HP MPIO Full Featured DSM for P9000 family of Disk Arrays 4.02.00 installation and reference guide (AA-RVJ6M-TE, October 2010)

Device Serial No.:50 142460C01
Cleanup the failed path information for this LUN (y/n)? y
Cleanup Succeeded. Verify by issuing "hpdsm devices" command.
Example:
hpdsm cleanup device=all
Successful for all the devices. Verify by issuing "hpdsm devices" command.
hpdsm notify
Syntax: hpdsm notify event=notification_event_number time=number_of_minutes
The hpdsm notify command defines user notification of events. The time attribute defines the number
of minutes that elapses from the time the event occurs until the user is notified. The maximum value
that can be entered is 35000 minutes.
NOTE:
Syntax: hpdsm notify event=notification_event_number
The above command will make the notification to wait indefinitely until the user terminates the wait
(with Ctrl-C).
Managing storage arrays using the HP MPIO P9000 DSM with the CLI utility32