WBEM Profiles Guide

Version 2.0.0 33
9.5.3 Drive Failed Rebuild complete
HPSAS_StorageExtent:001
OPStatus = “OK”
HPSAS_StorageExtent:003
Spare
OPStatus = “ERROR”
HPSAS_StoragePool:1
Concrete Pool
ConcreteComponent
ConcreteComponent
HPSAS_StorageRedundancySet:A
MemberOfCollection
MemberOfCollection
HPSAS_StorageExtent:004
OPStatus = “OK”
IsSpare
HPSAS_StorageVolume:100
OpStatus = “OK”
AllocatedFromStoragePool
Figure 16 - HP SAS HBA profile: Drive Failed Rebuild complete
Figure shows that the rebuild operation has completed. The OperationalStatus values are now “OK” for
the StorageVolume and the Spare Drive since rebuild is complete and redundancy has been restored.
Now the spare drive has become the data drive for the Storage Pool and the failed drive is now a spare
with “Error” status value.