WBEM Profiles Guide

22 Version 2.0.0
7.1.10 HPSAS_DiskDrive. SSDWearStatus
This value indicates the wearout status of the Solid State drive.
Table 21 - HP SAS HBA profile: HPSAS_DiskDrive.DrivePlacement
Value ValueMap
0
Unknown
1
OK
2
56 day threshold passed
3
5 percent threshold passed
4
2 percent threshold passed
5
SSD Wear Out
7.1.11 HPSAS_DiskDrive.SmartCarrierAuthStatus
This value indicates the status of the Smart Carrier Authentication if the controller supports hard drive and
SmartCarrier Authentication.
Table 22 - HP Smart Array profile: HPSAS_DiskDrive.SmartCarrierAuthStatus
Value ValueMap
0
Not Supported
1
Not Authenticated
2
Authenticated
3
Other
7.1.12 HPSAS_DiskDrive.OtherSmartCarrierAuthStatus
A string that describes the authentication status of the element when the
HPSAS_DiskDrive.SmartCarrierAuthStatus property is set to 3 ("Other"). This property must be set to null
when HPSAS_DiskDrive.SmartCarrierAuthStatus is any value other than 3.
7.2 HPSAS_StorageVolume
The HPSAS_StorageVolume class has been extended from CIM_StorageVolume class as defined in
SNIA Block Services profile.
7.2.1 HPSAS_StorageVolume.PercentComplete
During a rebuild operation, this will indicate progress as a percentage value. Note this value shall only be
populated when a rebuild operation is being performed on this logical volume.
7.2.2 HPSAS_StorageVolume.FaultTolerance
Enumeration to indicate which type of raid is currently configured for a logical volume. Supported values
are:
Table 7 - HP SAS HBA profile: HPSAS_StorageVolume.FaultTolerance
Value ValueMap
0
Unknown
1
RAID 0
2
RAID 1
3