WBEM Profiles Guide
Version 1.0.1 11
The HP_StorageEnclosure can contain multiple drive cages represented by instances of HP_DriveCage.
Each instance of HP_DriveCage is associated with the enclosure it is contained within
(HP_StorageEnclosure) via the association CIM_Container.
6.1 Location information
Container
SystemPackaging
HP_StorageEnclosureProcessor
HP_StorageEnclosure
HP_DriveCage
HP_Location
ElemInfoTagDesc = Port
HP_Location
ElemInfoTagDesc = ChassisName,
Box
PhysicalElementLocation
PhysicalElementLocation
CIM_PhysicalPackage (Disk)
Disk Drive Lite Subprofile
Container
HP_Location
ElemInfoTagDesc = Bay, SCSI ID
PhysicalElementLocation
Figure 2 – HP Storage Enclosure profile: Location specification
Location information can be determined through containment relationship within the overall storage
enclosure chassis represented by an instance of HP_StorageEnclosure. Implementations shall include an
instance of HP_Location associated to each physical package by CIM_PhysicalElementLocation.
6.2 Software Inventory
The Firmware version of the enclosure will be reported using the DMTF Software Inventory Profile
(DSP1023).
An instance of CIM_SoftwareIdentity shall be associated with each HP_StorageEnclosureProfile instance
via CIM_ElementSoftwareIdentity association. (See Figure 1).