P00116_-_HP_Power_Supply_Physical_Asset_Profile
Version 1.0.2 11
10 CIM Elements
The implementation requirements for the classes and properties described in this section are defined in
the “Implementation Requirements” section (Section 7).
Table 2 – CIM Elements – HP Power Supply Profile
Element Name Requirement Description
Classes
HP_PowerSupplyModule Mandatory See Sections 7.1 and 10.1
HP_RegisteredProfile Mandatory See Section 10.2
HP_RealizesPowerSupply Mandatory See Sections 7.2 and 10.3
HP_SystemPhysicalPowerSupply Mandatory See Sections 7.3 and 10.4
HP_PowerSupplyInSlot Conditional See Sections 7.4 and 10.5
Indications
None defined in this profile
10.1 HP_PowerSupplyModule
HP_PowerSupplyModule is used to represent a power supply module in a managed system.
Table 3 – Class: HP_PowerSupplyModule
Properties Requirement Notes
RemovalConditions Mandatory See Section 7.1.1
10.2 HP_RegisteredProfile
The HP_RegisteredProfile class is defined by the HP Profile Registration Profile.
Table 4 – Class: HP_RegisteredProfile
Properties Requirement Description
RegisteredName Mandatory "HP Power Supply Physical Asset"
RegisteredVersion Mandatory “1.0.2”
RegisteredOrganization Mandatory Other (1)
OtherRegisteredOrganization Mandatory “HP WBEM TC”
10.3 HP_RealizesPowerSupply
HP_RealizesPowerSupply is used to represent the association between HP_PowerSupply and
HP_PowerSupplyModule.
Table 5 – Class: HP_RealizesPowerSupply
Properties Requirement Notes
Antecedent Mandatory
Key: References HP_PowerSupplyModule
Dependent Mandatory
Key: References HP_PowerSupply