HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
HP Insight Manager WBEM Base Server Provider Overview 7
Property Name
Property Implementation
SerialNumber
The computer system physical serial number string.
IdentifyingNumber
The computer system physical GUID string.
IncludedInSolution
Boolean property that indicates whether the system is part of aggregate
systems.
SolutionName
This property is a string that shall contain a unique name that describes
the product family for the aggregate product along with the version.
Notation: ā<Solution Name> vX.Y.Zā where X is Major number, Y is
Minor number and Z is Update number Eg. āCloudSystem Matrix
v6.3.1aā. This property is only implemented if
HP_ComputerSystem.IncludedInSolution is True.
Model
The computer system model string.
SMX_ComputerSystem
1-2-1-1 Implemented Methods for SMX_ComputerSystem Class
Method Name
Method Implementation
SendTestIndication
Method Parameters:
EventID, number of test event to send:
101 - Send Information Test Indication
102 - Send Warning Test Indication
103 - Send Critical Test Indication
Return Values:
0 - request to send indication successful
1 - method unsupported
2 - request to send indication failed
3 - provider is busy processing previously requested indication, try again
4
- EventID is not one of the defined values
Exception: CIM_ERR_INVALID_PARAMETER - EventID is the wrong type,
does not exist or other internal error.
1-2-2 SMX_ComputerSystemChassis Class
The SMX_ComputerSystemChassis class implements the HP_ComputerSystemChassis class to model
the physical system chassis. There is only one instance of
SMX_ComputerSystemChassis instantiated on a
server.