HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
HP Insight Management WBEM System Memory Provider 29
Property Name
Property Implementation
Where: TargetConfiguration
is SMX_MemoryRedundancySet.TargetConfiguration.
AlertingManagedElement
WBEM Path of SMX_MemoryRedundancySet instance representing the
Memory Redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
3
ProviderName
HP Memory
RecommendedActions
Check the Advanced Memory Protection configuration and
replace the memory board and memory modules as
necessary.
HP_AlertIndication
Summary
Advanced Memory Protection degraded
EventCategory
3 (Memory)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Advanced Memory Protection Degraded
1-3-5 SMX_MemoryIndication: Memory Recovered from
Degraded Redundancy
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
The Advanced Memory Protection(AMP) system is operating
normally in the targeted configuration. If redundancy
was previously degraded, redundancy has been restored.
(TargetConfiguration) Where: TargetConfiguration
is SMX_MemoryRedundancySet.TargetConfiguration.
AlertingManagedElement
WBEM Path of SMX_MemoryRedundancySet instance representing the
Memory Redundancy.
AlertingElementFormat
2 (CIMObjectPath)