HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM System Memory Provider 27
Property Name
Property Implementation
RackName
Rack name, if one exists
RackUUID
Rack Unique Identifier, if one exists
BladeName
HP_ComputerSystem.Name
BladeBay
HP_BladeCSLocation.LocationInformation[0]
1-3-2 SMX_MemoryIndication: Memory Module Predictive
Failure
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
A memory module has failed or is predicted to fail.
(MemoryModuleCaption) where MemoryModuleCaption is
the
SMX_MemoryModule.Caption
for the failing memory module
AlertingManagedElement
WBEM Path of SMX_MemoryModule instance representing the memory
module
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Memory
RecommendedActions
Check the memory configuration and replace memory as
necessary.
HP_AlertIndication
Summary
Memory module has failed or is predicted to fail
EventCategory
3 (Memory)
ProbableCause
1 (Other)
ProbableCauseDescription
Memory Module Failed or Predicted to Fail