HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

Property Name
Property Implementation
RecommendedActions
Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
HP_AlertIndication
Summary
Cooling redundancy lost
EventCategory
23 (System Cooling)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Cooling Redundancy has been Lost
1-3-9 HP_DeviceIndication: Fan Redundancy Restored
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
Cooling redundancy for the system has been restored.
(RedundancySetCaption)
Where: RedundancySetCaption is
SMX_FanRedundancySet.Caption
of the cooling redundancy set with
restored redundancy.
AlertingManagedElement
WBEM Path of SMX_FanRedundancySet instance representing the cooling
redundancy set with restored redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
8
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Cooling redundancy restored
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)