HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
1-3-6 HP_DeviceIndication: Fan Degraded
.
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
4 (Minor)
CIM_AlertIndication
Description
A fan has degraded. <FanCaption>
Where: <FanCaption> is the SMX_Fan.Caption
for the fan that has
degraded.
AlertingManagedElement
WBEM Path of
SMX_Fan
instance representing the degraded fan.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
9
ProviderName
HP Cooling
RecommendedActions
Check the degraded fan and replace if necessary.
HP_AlertIndication
Summary
Fan degraded
EventCategory
23 (System Cooling)
ProbableCause
1
(Other)
ProbableCauseDescription
Fan Degraded
1-3-7 HP_DeviceIndication: Fan Redundancy Reduce
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
A fault tolerant fan is no longer providing cooling for a cooling redundancy
set. <RedundancySetCaptio>)
Where: <RedundancySetCaption> represents the
SMX_FanRedundancySet.Caption for the redundancy set with reduced