HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

The following indications are implemented for Proliant server platforms where available. System Fan
indications are described below.
1-3-2 HP_DeviceIndication: Fan Removed
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2
(Information)
CIM_AlertIndication
Description
A fan has been removed <Fan>
Where: <Fan> is the fan number that was removed.
AlertingManagedElement
WBEM Path of the SMX_Fan instance.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Cooling
RecommendedActions
Check the fan configuration and ensure that this fan
was removed intentionally.
HP_AlertIndication
Summary
Fan removed
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Removed
1-3-3 HP_DeviceIndication: Fan Inserted
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication