HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

Property Name
Property Implementation
ElementName
Short
description of the fan speed sensor from the name displayed by the MP
or iLO and the location.
For example:
Fan speed sensor for Fan 1 at CabinetFan=01
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if fan sensor is operating properly
StatusDescriptions[0]
Fan speed sensor is operating properlyif
OperationalStatus[0] is 2 (OK)
HealthState
5 (OK) if fan sensor is operating properly
Name
Name of fan speed sensor from the name displayed by the MP or iLO and
the location.
For example:
Fan speed sensor for Fan 1 at CabinetFan=01
CIM_LogicalDevice
CreationClassName
SMX_FanSpeedSensor
DeviceID
Unique identifier for fan slot.
SystemCreationClassName
HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_Sensor
SensorType
5 (Tachometer)
CurrentState
Normal
PossibleStates
Array can contain any of the following values:
PossibleStates[0] = ”Normal”;
CIM_NumericSensor
CurrentReading
Current reading of fan speed sensor