HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
1-2-10 SMX_FanElementLocation Class
The SMX_FanElementLocation class is used to represent an association between the CIM_Location
and CIM_ManagedElement classes.
The following table lists the properties implemented.
Property Name
Property Implementation
Element
References CIM_ManagedElement
PhysicalLocation
References CIM_Location
1-2-11 SMX_FanModule Class
The SMX_FanModule class is used to model physical fans on servers. Fan numbers for existing instances do
not change when other fans are added and removed.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this fan from the name displayed by the MP or iLO and
location.
For example:
Fan 1 at CabinetFan=01
Description
Description of this fan module, including ElementName, type and status.
For example:
<ElementName> provides cooling for FanType. <StatusDescription>
Where: <ElementName> represents the value of ElementName, FanType
represents the corresponding string value of the FanType enumeration and
<StatusDescription> represents the value of
StatusDescriptions[0].
ElementName
Name of this fan from the name displayed by the MP or iLO and location.
For example:
Fan 1 at CabinetFan=01
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if fan is operating properly;
3 (Degraded) – if fan is degraded;
6 (Error) – if fan has failed