HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
CIM_ManagedElement
Caption
Short description of this redundancy set, for example: Cooling
Redundancy Set <n>
Where: <n> represents the number of the redundancy set instance.
Description
Description of this redundancy set
For example:
Cooling Redundancy Set <n> is collection of fault tolerant fans that
provide redundant cooling
Where: <n> represents the number of the redundancy set instance.
ElementName
User printable name for this cooling redundancy set.
For example:
Cooling Redundancy Set <n>
Where: <n> represents the number of the redundancy set instance.
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this cooling redundancy instance.
CIM_RedundancySet
MaxNumberSupported
Represents the maximum number of fans supported for this redundancy set.
MinNumberNeeded
Represents the minimum number of fans needed to function.
TypeOfSet
3 (Load Balanced)
LoadBalanceAlgorithm
0 (Unknown)
RedundancyStatus
0 (Unknown) – if the redundancy status is unknown;
2 (Fully Redundant) – if all fans in the set are operating properly and enough
to achieve redundancy;
3 (Degraded Redundancy) – if there are at least enough fans for the
redundancy set to provide cooling, but fans have failed;
4 (Redundancy Lost) – if there are not enough fans required to achieve
redundancy, but enough for the redundancy set to provide cooling;
5 (Overall Failure) – if there are not enough fans operating properly for the
redundancy set to provide cooling.
1-2-4 SMX_MemberOfFanRedundancy Class
The SMX_MemberOfFanRedundancy class is used to represent an association between the HP_Fan and
HP_FanRedundancySet classes. The following table lists the properties implemented.