HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
HP Insight Management WBEM Smart Array Provider 120
Property Name
Property Implementation
ProbableCause
51 (Temperature Unacceptable )
ProbableCauseDescription
Temperature Status Changed to Critical
NetworkAddresses
Contains a list of all the IP addresses of the computer system generating the
indication
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format: <major>.<minor>.<build>
ProviderVersion
For example:
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the indication
SystemSerialNumber
Serial number of the computer system generating the indication
SystemProductID
Product ID of the computer system generating the indication
SystemModel
Model name of the computer system generating the indication
SystemGUID
Platform GUID of the computer system generating the indication
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3
(Enclosure) the properties that follow and
are indicated with an asterisk (*) below will be populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name, if one exists
RackUID *
Rack Unique Identifier, if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial number string
when running in a Virtual Connect environment
SystemVirtualUUID
Conditional property containing the virtual system UUID when running in a
Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name string when running in