HP Insight Management WBEM Smart Array Provider 113
Property Name
Property Implementation
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the indication
HP_AlertIndication
Summary
Power supply status Redundant Degraded
EventCategory
17 (Primary Storage Power)
ProbableCause
89
(Power supply failure)
ProbableCauseDescription
Redundant Power Supply Degraded
NetworkAddresses
Contains a list of all the IP addresses of the computer system generating the
indication
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format: <major>.<minor>.<build>
ProviderVersion
For example:
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the indication
SystemSerialNumber
Serial number of the computer system generating the indication
SystemProductID
Product ID of the computer system generating the indication
SystemModel
Model name of the computer system generating the indication
SystemGUID
Platform GUID of the computer system generating the indication
SolutionProductModel
Conditional property containing the Solution Name string when running in
a aggregate product environment in the format <aggregate product family
name> v<major>.<minor>.<update>
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3
(Enclosure) the properties that follow and
are indicated with an asterisk (*) below will be populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name