HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 112
Property Name
Property Implementation
SystemVirtualUUID
Conditional property containing the virtual system UUID when running in a
Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation
Enclosure Location string
For example:
Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-3-19 HP_DeviceIndication: Enclosure Power Supply Status
changed to Redundant Degraded
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Subsystem status has changed
to Degraded Redundancy.
AlertingManagedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
303
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.