HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 102
Property Name
Property Implementation
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3
(Enclosure) the properties that follow and
are indicated with an asterisk (*) below will be populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial number string
when running in a Virtual Connect environment
SystemGUID
Platform GUID of the computer system generating the indication
VariableNames[]
FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[]
String (1)
uint32 (5)
VariableValues[]
FailureDescriptionshort description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
1-3-15 HP_DeviceIndication: Controller Cache Status -
Temporarily Disabled
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication