HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 99
Property Name
Property Implementation
SystemProductID
Product ID of the computer system generating the indication
SystemModel
Model name of the computer system generating the indication
SystemGUID
Platform GUID of the computer system generating the indication
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3
(Enclosure) the properties that follow and
are indicated with an asterisk (*) below will be populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name, if one exists
RackUID *
Rack Unique Identifier, if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial number string
when running in a Virtual Connect environment
SystemVirtualUUID
Conditional property containing the virtual system UUID when running in a
Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name string when running in
a aggregate product environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation
Array Controller Location string
For example:
Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer
HWSerialNumber
Array Controller Serial Number
VariableNames[]
FailureDescription
CacheSizeTotal
CacheSerialNumber