HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 98
Property Name
Property Implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller battery status changed to
Failed.
AlertingManagedElement
WBEM Path to SMX_SAArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
8
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check battery connection and replace if necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the indication
HP_AlertIndication
Summary
Controller battery status Failed
EventCategory
6 (Primary Storage)
ProbableCause
92 (battery failure)
ProbableCauseDescription
Controller Battery Status Changed to Failed
NetworkAddresses
Contains a list of all the IP addresses of the computer system generating the
indication
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format: <major>.<minor>.<build>
ProviderVersion
For example:
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the indication
SystemSerialNumber
Serial number of the computer system generating the indication