HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
HP Insight Management WBEM Smart Array Provider 97
Property Name
Property Implementation
SystemVirtualUUID
Conditional property containing the virtual system UUID when running in a
Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name string when running in
a aggregate product environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation
Array Controller Location string
For example: Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer
HWSerialNumber
Array Controller Serial Number
VariableNames[]
FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[]
String (1)
uint32 (5)
VariableValues[]
FailureDescription – short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
1-3-13 HP_DeviceIndication: Controller Battery Status Changed
to FAILED
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)