HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
HP Insight Management WBEM Smart Array Provider 82
Property Name
Property Implementation
DeviceOperationalStatusPrevious
Previous OperationalStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
SMX_SAStorageVolume.OperationalStatus[1]
(This index is only populated if there is additional Vendor unique
status available)
1-3-7 SMX_SAStorageVolumeIndication: Logical Drive Status
Changed to ERROR
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive status has changed to Error.
AlertingManagedElement
WBEM Path of SMX_SAStorageVolume class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
102
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the
indication
HP_AlertIndication