HP Insight Management WBEM Smart Array Provider 79
Property Name
Property Implementation
VariableTypes[]
String (1)
uint16 (4)
VariableValues[]
FailureDescription – short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription – last failure reason string from the
drive. HPSA_DiskDrive.OperationalStatus[1]
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example:
SmartArray 642 in Slot 2
1-3-6 HPSA_StorageVolumeIndication : Logical Drive Status
Changed to OK
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2
(Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive status has changed from a non-OK
state to OK.
AlertingManagedElement
WBEM Path of SMX_SAStorageVolume Class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
101