HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 77
Property Name
Property Implementation
out.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
206
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array (
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the
indication
HP_AlertIndication
Summary
Physical drive status in Predictive Failure due
to SSD wears out.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
The Physical drive status has changed to
Predictive Failure due to Solid State drive wear
out.
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format:
<major>.<minor>.<build>
ProviderVersion
For example:
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the indication
SystemSerialNumber
Serial number of the computer system generating the indication
SystemProductID
Product ID of the computer system generating the indication