HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 76
Property Name
Property Implementation
Port:1E Box: 1 Bay 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
HWSerialNumber
Physical Disk Serial Number
VariableNames[]
FailureDescription
DriveInterface
LastFailureDescription
VariableTypes[]
String (1)
uint16 (4)
VariableValues[]
FailureDescriptionshort description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescriptionlast failure reason string from the
drive. HPSA_DiskDrive.OperationalStatus[1]
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example:
SmartArray 642 in Slot 2
1-3-5 HP_DeviceIndication: Physical Drive Status Changed to
Predictive Failure due to Solid State Drive Wearout
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
The Physical drive status has changed to
Predictive Failure due to Solid State drive wear