HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 68
Property Name
Property Implementation
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example:
SmartArray 642 in Slot 2
VariableNames[]
FailureDescription
DriveInterface
LastFailureDescription
VariableTypes[]
String (1)
uint16 (4)
VariableValues[]
FailureDescriptionshort description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescriptionlast failure reason string from the
drive.
HPSA_DiskDrive.OperationalStatus[1]
1-3-2 HP_DeviceIndication: Physical Drive Status Changed to
ERROR
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
Severity
5
(Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Error.
AlertingManagedElement
WBEM Path of
SMX_SADiskDrive
class