HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM Smart Array Provider 42
Property Name
Property Implementation
ElementName
For Primodial Pools:
Controller name and <physical location>.
Refer to
“Physical Location” for more information.
For example:
“Smart Array in Slot=3” for internal
For example:
“Smart Array Embedded Controller=7” for embedded controller
where 7 is the internal identifier for the embedded controller.
For Concrete Pools:
Controller name and <physical location>, Array Identifier
For example: Smart Array in Slot=3:0
CIM_Capabilities
InstanceID
Key: Opaque key
CIM_StorageCapabilities
DataRedundancyDefault
1 (When number of drives is an odd number)
2 (When number of drives is an even number For example: Pool
can be configured for mirroring)
DataRedundancyMax
1 (When number of drives is an odd number)
2 (When number of drives is an even number For example: Pool
can be configured for mirroring)
DataRedundancyMin
1
DeltaReservationDefault
0
DeltaReservationMax
0
DeltaReservationMin
0
ElementType
5 (Storage Pool)
NoSinglePointOfFailure
True - When number of drives > 1
(For example: Pool can be configured for redundancy)
False
When number of drives <= 1
NoSinglePointOfFailureDefault
True - When number of drives > 1
(For example: Pool can be configured for redundancy)
False
When number of drives <= 1