HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
HP Insight Management WBEM System Temperature Sensor Provider 7
1-3-1 HP_AlertIndication: Temperature Sensor Threshold
Exceeded
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication.
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication.
CIM_AlertIndication
Description
A temperature sensor has detected that the
temperature has exceeded the normal operating
range. <SensorCaption>
Where: <SensorCaption> is the SMX_NumericSensor.Caption
for the sensor that has failed.
AlertingManagedElement
WBEM Path of the SMX_NumericSensor instance representing the
temperature sensor detecting the exceeded threshold.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Temperature
RecommendedActions
Ensure that the system is adequately ventilated.
Check for proper room temperature and
internal/external airflow. Add or repair fans and
air baffling if necessary.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Temperature threshold exceeded detected
EventCategory
23 (System Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription
Temperature Threshold Exceeded Detected