HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Management WBEM System Temperature Sensor Provider 3
Property Name
Property Implementation
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if temperature reported by the sensor is within normal operating
range;
2 (OK) if temperature reported by the sensor has exceeded its non-critical
threshold and has set fans to full speed;
6 (Error) if temperature reported by the sensor has exceeded its threshold
and the system is gracefully shutting down.
StatusDescriptions[0]
Temperature reported by the sensor is within normal
operating rangeif temperature reported by the sensor is within
normal operating range;
Temperature reported by the sensor has exceeded its
non-critical threshold and the fans have been set to
full speedif temperature reported by the sensor has exceeded its
threshold and has set fans to full speed;
Temperature reported by the sensor has exceeded its
threshold and the system is gracefully shutting down
if
OperationalStatus is 6 (Error)
HealthState
5 (OK) if OperationalStatus[0] value is 2 (OK);
20 (Major Failure) if OperationalStatus[0] value is 6 (Error)
Name
Temperature Sensor n where n represents the number of the
temperature sensor instance(s).
CIM_LogicalDevice
CreationClassName
SMX_NumericSensor
DeviceID
Unique identifier for this temperature sensor instance.
SystemCreationClassName
HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_Sensor
SensorType
2 (Temperature)