HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets

HP Insight Manager WBEM Base Server Provider Overview 21
Property Name
Property Implementation
CIM_AlertIndication
Description
The system has rebooted from an Automatic Server
Recovery (ASR) event.
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Recovery
RecommendedActions Determine the nature of the ASR event and take
corrective action.
HP_AlertIndication
Summary
ASR reboot occurred
EventCategory
16 (System Power)
ProbableCause
111
(Timeout)
ProbableCauseDescription
ASR reboot occurred
1-3-6 HP_DeviceIndication: Thermal Reboot Occurred
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
The system has rebooted from thernal shutdownevent.
AlertType
5 (Device Alert)
EventID
2
ProviderName
HP Recovery
RecommendedActions
Replace any failed or removed fans. Insure the air
flow into, out of, and within the system chassis is
not obstructed.
HP_AlertIndication
Summary
Thermal reboot occurred
EventCategory
23 (System Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription
Thermal reboot occurred