HP Insight Management Power Supply Provider Overview 14
Property Name
Property Implementation
CIM_PhysicalPackage
ConnectorLayout
6 (Slot)
Number
<n>
Where: <n> represents the number of the power supply slot.
1-2-15 SMX_SystemPowerSupplySlot Class
The SMX_SystemPowerSupplySlot class extends the CIM_Container class and association of the
HP_ComputerSystemChassis instance with HP_PowerSupplySlot.
The following table lists the properties implemented.
Property Name
Property Implementation
GroupComponent
References HP_ComputerSystemChassis
PartComponent
References HP_PowerSupplySlot
1-2-16 SMX_PowerSupplyInSlot Class
The SMX_PowerSupplyInSlot class extends the CIM_ElementInConnector class and associates the
HP_PowerSupplySlot instance with HP_PowerSupplyModuleinstances.
The following table lists the properties implemented.
Property Name
Property Implementation
Antecedent
References HP_PowerSupplySlot
Dependent
References HP_PowerSupplyModule
1-2-17 SMX_Power Meter
SMX_PowerMeter is used to model power utilization on Servers. Please note: power supply numbers for
existing instances do not change when other power supplies are added and removed. Not all systems
support reporting power utilization .
Property Name
Property Implementation
CIM_ManagedElement