HP Insight Management Power Supply Provider Overview 11
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
Description
Description of this power supply module, including ElementName, Type and
Status.
For example:
ElementName provides power for PowerSupplyType.
StatusDescription
Where: ElementName represents the value of ElementName,
PowerSupplyType represents the corresponding string value of the
PowerSupplyType enumeration and StatusDescription represents the
value of
StatusDescriptions[0]
.
ElementName
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if power supply is operating properly;
3 (Degraded) if power supply is degraded;
6
(Error) if power supply has failed
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properlyif OperationalStatus[0]
is 2 (OK);
Power Supply is degradedif OperationalStatus[0] is 3
(Degraded)
Power Supply has failedif OperationalStatus is 6 (Error)
HealthState
5 (OK) if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) if power supply has failed