HP integrated VMware ESXi 5.0 U1 June 2012 Datasheets
HP Insight Management Power Supply Provider Overview 3
behavior and the Managed Object Format interpretation is within parenthesis. If other values are returned,
a problem is indicated.
Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity
(cellular and non-cellular) systems. The location related properties and implementation values are
determined based on the server type so they may differ.
1-2-1 SMX_PowerSupply Class
The SMX_PowerSupply class is used to model power supplies on servers. Power supply numbers for
existing instances do not change when other power supplies are added and removed.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this power supply for the name displayed by the MP or
iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
Description
Description of this power supply, including ElementName,
PowerSupplyType and StatusDescription[0] and
StatusDescription[1].
For example:
Elementname provides power for
PowerSupplyType.StatusDescription
Where: Elementname represents the value of ElementName,
PowerSupplyType represents the corresponding string value of the
PowerSupplyType enumeration, and StatusDescription represents the
value of
StatusDescriptions[0]
and
StatusDescription[1].
ElementName
Short description of this power supply for the name displayed by the MP or
iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if power supply is operating properly;
3 (Degraded) – if power supply is degraded;
6
(Error) – if power supply has failed
OperationalStatus[1]
Extended Warning and Error status. See the MOF and Profile