HP Insight Manager WBEM Base Server Provider Overview 17
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_Dependency
CIM_ElementSoftwareIdentity
UpgradeCondition
3 (Owner Upgradeable)
ElementSoftwareStatus
The ElementSoftwareStatus array will contain the following if the
Antecedent refers to an instance of an Active Firmware:
ElementSoftwareStatus[0]:
6 (Installed)
ElementSoftwareStatus[1]:
2 (Current)
The ElementSoftwareStatus array will contain the following if the
Antecedent refers to an instance of a Redundant Firmware:
ElementSoftwareStatus[0]:
6 (Installed)
ElementSoftwareStatus[1]:
4
(Fallback)
SMX_SystemElementFirmwareIdentity
Antecedent
References SMX_SystemFirmware
Dependent
References SMX_ComputerSystem
1-3 Supported Indications
The following table describes the properties that are common to all of the SMX Base Server Provider
indications that are implemented for server platforms, where available.
The following table lists the common properties implemented.
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of the indication
IndicationTime
Time of indication
CIM_AlertIndication
EventTime
Time of the event or time of the indication if event time unknown