HP integrated VMware ESXi 5.
1 HP Insight Manager WBEM Base Server Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Base Server provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
Provider part of the HP Insight Management WBEM providers. Configuring the Provider This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. 1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Computer system DNS name returned by uname. Description Computer system DNS name returned by uname. ElementName Computer system DNS name returned by uname. CIM_ManagedSystemElement Status Same as OperationalStatus[0]. OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of any connected subsystem.
Property Name Property Implementation StatusDescriptions[0] will contain one of the following corresponding to OperationalStatus[0]: One or more of the subsystems that make up this computer system have an OperationalStatus value of Unknown One or more of the subsystems that make up this computer system have an OperationalStatus value of Other One or more of the subsystems that make up this computer system have an OperationalStatus value of Degraded StatusDescriptions One or more of the subsystems that ma
Property Name Property Implementation CIM_ComputerSystem OtherIdentifyingInfo[0]: Where: is the computer system physical GUID string. OtherIdentifyingInfo[1]: Where: is the computer system MAC address. OtherIdentifyingInfo[2]: : Where: is the computer system model string; and Serial_Number_String is the computer system physical serial number string.
Property Name Property Implementation IdentifyingDescriptions[0]: CIM:GUID IdentifyingDescriptions[1]: CIM:MAC IdentifyingDescriptions[2]: CIM:Model:SerialNumber IdentifyingDescriptions[3]: IdentifyingDescriptions CIM:Tag IdentifyingDescriptions[4] CIM:CorrelatableID IdentifyingDescriptions[5] HPQ:ProductID IdentifyingDescriptions[6] HPQ:SMXTarget Dedicated 0 (Not Dedicated) HP_ComputerSystem Name Computer system DNS name returned by uname.
Property Name Property Implementation SerialNumber The computer system physical serial number string. IdentifyingNumber The computer system physical GUID string. IncludedInSolution Boolean property that indicates whether the system is part of aggregate systems. This property is a string that shall contain a unique name that describes the product family for the aggregate product along with the version. Notation: “ vX.Y.
The following table lists the properties implemented. Property Name Property Implementation CIM_PhysicalElement Unique value for instance. Tag For example: 1 CreationClassName SMX_ComputerSystemChassis ElementName Computer system product name (model) string. Manufacturer Computer manufacturer string. Model Computer system product name (model) string. SerialNumber Computer system physical serial number.
Property Name Property Implementation 0 (Unknown) RackMountable 1 (True) 2 (False) HP_ComputerSystemChassis Computer system product ID string ProductID For example: 123456-123. VirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. VirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. Indicates the installed and enabled state of the Trusted Platform Module.
1-2-4 SMX_OperatingSystem Class The SMX_OperatingSystem class implements the CIM_OperatingSystem class to model the system operating system. There is only one instance of SMX_OperatingSystem instantiated on a server. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption On Linux, first line of /etc/issue. On ESXi, output of vmware -v Description Output of uname -v. ElementName Output of uname -s.
Property Name Property Implementation CreationClassName SMX_OperatingSystem Version Output of uname -r. OtherTypeDescription On Linux, NULL On ESXi, Embedded On Linux, 36 (Linux) OSType On ESXi, 39 (VM) LocalDateTime Current time. LastBootUpTime Time when the operating system was last booted SMX_OperatingSystem 1-2-5 SMX_RunningOS Class The SMX_RunningOS class implements the CIM_RunningOS class and associates the SMX_ComputerSystem instance and an SMX_OperatingSystem instance.
SMX_InstalledOS 1-2-7 SMX_SMXSoftwareIdentity Class The SMX_SMXSoftwareIdentity implements the HP_SoftwareIdentity class to model the SMX software identification information. The following table lists the properties implemented.
Property Name Property Implementation MajorVersion The first numeric value in the VersionString. MinorVersion The second numeric value in the VersionString. RevisionNumber The third numeric value in the VersionString. VersionString Version of SMX, for example: 02.00.00. Manufacturer Hewlett Packard Company Classifications[0] 5 (Instrumentation) IsEntity TRUE TargetOSTypes[0] On Linux, 36. On ESXi, 39 (VM).
InstalledSoftware References SMX_SMXSoftwareIdentity System References SMX_ComputerSystem SMX_SMXInstalledSoftwareIdentity 1-2-9 SMX_SystemFirmware Class The SMX_SystemFirmware class implements the HP_SoftwareIdentity class and describes the firmware found on the server system. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the firmware.
Property Name Property Implementation Opaque string using HPQ as OrgID InstanceID For example: HPQ:SMX_SystemFirmware: Where: is used to identify the instance. For example: HPQ:SMX_SystemFirmware:1 MajorVersion The firmware major version. MinorVersion The firmware minor version. VersionString The firmware version.
InstalledSoftware References SMX_SystemFirmware System References SMX_ComputerSystem 1-2-11 SMX_SystemElementFirmwareIdentity Class The HP_SystemElementFirmwareIdentity class implements the HP_ElementSoftwareIdentity class and associates the HP_ComputerSystem instance and SMX_SystemFirmware instances.
The following table lists the properties implemented.
Property Name Property Implementation SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication Provider Version in the format VV.UU.FF. ProviderVersion For example: 01.05.
Property Name Property Implementation RecommendedActions No action is recommended. HP_AlertIndication Summary WBEM Providers started indication Id:9 ProbableCause 1 (Other) ProbableCauseDescription WBEM Providers Started HP_DeviceIndication: WBEM Providers Informational Test Indication 1-3-2 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Informational) CIM_AlertIndication Description This is an information test event.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 2 ProviderName HP Test RecommendedActions No action is recommended.
Property Name Property Implementation CIM_AlertIndication Description The system has rebooted from an Automatic Server Recovery (ASR) event. AlertType 5 (Device Alert) EventID 1 ProviderName HP Recovery RecommendedActions Determine the nature of the ASR event and take corrective action.
1-3-7 HP_DeviceIndication: Fan Failure Reboot Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The system has rebooted from fan failure shutdown event. AlertType 5 (Device Alert) EventID 3 ProviderName HP Recovery RecommendedActions Replace any failed or removed fans.
Property Name Property Implementation ProbableCause 89 (Power Supply Failure) ProbableCauseDescription VRM failure reboot occurred HP_DeviceIndication: POST Occurred 1-3-9 Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description Power-On Self-Test errors occurred during the last system startup.
1 HP Insight Management WBEM Blade System Lite Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Blade System Lite provider extends the management capability of referencing profiles by adding the capability to represent the Distributed Management Task Force (DMTF) Modular System Profile in HP specific ways. While this profile is based on the DMTF Modular System Profile, it does not conform to that profile.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
Property Name Property Implementation A description of the class. For example, if enclosure name exists: Caption HP BladeSystem enclosure otherwise: HP BladeSystem enclosure A description of the class. For example, if enclosure name exists: Description HP BladeSystem enclosure otherwise: HP BladeSystem enclosure A description of the class.
Property Name Property Implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName SMX_BladeEnclosureCS CIM_ComputerSystem Dedicated 2 (Other) OtherDedicatedDescriptions Modular IdentifyingDescriptions[0]: HPQ:ProductID IdentifyingDescriptions IdentifyingDescriptions[1]: CIM:Model:SerialNumber OtherIdentifyingInfo[0]: Where: is the blade
Property Name Property Implementation ProductID The product ID of the blade enclosure. RackName The name of the rack. RackUID The UUID of the rack. EnclosureName Then name of the blade enclosure. 1-2-2 SMX_BladeEnclosureCollection Class The SMX_BladeEnclosureCollection class implements the HP_BladeEnclosureCollection class to aggregate the enclosure’s group operational status. The following table lists the properties implemented.
Property Name Property Implementation GroupStatusDescriptions[0] per GroupOperationalStatus[0]: Server Blade Enclosure and Onboard Administrator status: Unknown GroupStatusDescriptions Server Blade Enclosure and Onboard Administrator status: OK Server Blade Enclosure and Onboard Administrator status: Degraded Server Blade Enclosure and Onboard Administrator status: Error HP_BladeEnclosureCollection 1-2-3 SMX_BladeSystemComponent Class The SMX_BladeSystemComponent class implements the HP_BladeSystemCom
Property Name Property Implementation Collection References HP_BladeEnclosureCollection Member References HP_BladeEnclosureCS 1-2-5 SMX_BladeEnclosureGroupHostedCollection Class The SMX_BladeEnclosureGroupHostedCollection class implements the HP_BladeEnclosureGroupHostedCollection class and associates the enclosure’s computer system instance to the blade enclosure collection instance. The following table lists the properties implemented.
Property Name Property Implementation A description of the class. For example, if enclosure name exists: Name HP BladeSystem enclosure otherwise: HP BladeSystem enclosure OperationalStatus 2 (OK), normal operation StatusDescriptions Server Blade Enclosure Firmware status: OK HealthState 5 (OK), normal operation CIM_LogicalElement CIM_SoftwareIdentity Opaque identifier using HPQfor OrgID. InstanceID For example: HPQ:SMX_BladeEnclosureFirmware:1.
The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the Blade location. Caption For example: Blade Computer System Bay Location Where: represents the blade bay slot position printed on the enclosure labeling. A description of the Blade location. Description For example: Blade Computer System Bay Location Where: represents the blade bay slot position printed on the enclosure labeling.
1-2-10 SMX_BladeCSElementLocation Class The SMX_BladeCSElementLocation class implements the HP_ElementLocation class and is used to represent an association between the CIM_Location and CIM_ManagedElement classes. Property Name Value Element References CIM_ComputerSystem PhysicalLocation References HP_BladeCSLocation 1-3 Provider Indications Indications Generated by the Provider This provider generates no indications.
1 HP Insight Management WBEM Configuration Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Configuration (Config) Record Log provider implements the Configuration Snapshot Log on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Record Log Profile (P00109) HP WBEM TC 1.
This provider supports the following classes: Schema Supported by the Provider • SMX_ConfigRecordLog • SMX_ConfigLogEntry • SMX_ConfigLogManagesRecord • SMX_ConfigUseOfLog The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the property name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation EnabledState 2 (Enabled) RequestedState 12 (Not applicable) EnabledDefault 2 (Enabled) CIM_Log MaxNumberOfRecords 1 – Only the most recent snapshot of the configuration will be available. CurrentNumberOfRecords Number of records in the Config log (SMX_ConfigLogEntry instances). LogState 2 (Normal) OverwritePolicy 2 (Wraps Never) CIM_RecordLog InstanceID HPQ:SMX_ConfigRecordLog:1 HP_CommonRecordLog TimeOfLastChange Time of last log change.
Property Name Property Implementation CIM_LogEntry InstanceID Opaque key. LogInstanceID SMX_ConfigRecordLog.InstanceID LogName SMX_ConfigRecordLog.Name RecordID Config record number. CreationTimeStamp Config log event creation time stamp. HP_CommonLogEntry RecordDataType 3 (Delimited) RawData Instances in CIM-XML encoding. MajorClass 21 (Config Snapshot) MinorClass 2 (None) 0 (Unknown) 36 (Linux) OSType 39 (VMware) SystemSerialNumber System serial number string from SMBIOS.
Log Reference HP_CommonRecordLog. Record Reference HP_CommonLogEntry. 1-2-4 SMX_ConfigUseOfLog Class The SMX_ConfigUseOfLog class implements the HP_UseOfLog class and associates the instance of HP_ComputerSystem with the instance of HP_CommonRecordLog. The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_UseOfLog HP_UseOfLog Antecedent Reference HP_CommonRecordLog. Dependent Reference HP_ComputerSystem.
1 HP Insight Management WBEM CPU Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) CPU provider implements and extends classes described in this document to model the system processors. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP CPU Profile (P00106) HP WBEM TC 1.1.0 HP CPU Consolidated Status Profile (P00107) HP WBEM TC 1.0.
Provider as part of the HP Insight Management WBEM providers. Configuring the Provider This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. 1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider returns instances in the root/hpq namespace.
implementation. When the Property Implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis. If other values are returned, a problem is indicated. Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity (cellular and non-cellular) systems. The location related properties and implementation values are determined based on the server type so they may differ.
Property Name Property Implementation 0 (Unknown) 2 (OK), when CPU is enabled and operational OperationalStatus 5 (Predictive Failure), when IML error info logged for this CPU 6 (Error), when CPU is disabled via POST error 10 (Stopped), when CPU is disabled via RBSU StatusDescriptions[0] text per OperationalStatus[0]: Unknown StatusDescriptions OK Error Stopped Predictive Failure 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 15 (Minor Failure)
Property Name DeviceID Property Implementation Proc where n is the processor number.
Property Name Property Implementation For x86 processors: Characteristics[0] 3 (32-bit Capable) Characteristics For x64 processors: Characteristics[0] 3 (32-bit Capable) Characteristics[1] 2 (64-bit Capable) Number of enabled and operational cores for this processor NumberOfEnabledCores For example: 1, 2, 4 Stepping Stepping for processor Role Processor Role UniqueID Unique identifier for processor HP_Processor SMX_Processor 1-2-2 SMX_ProcessorCapabilities Class The SMX_ProcessorCapabilities c
Property Name Property Implementation CIM_EnabledLogicalElementCapabilities ElementNameEditSupported False RequestedStatesSupported None CIM_ProcessorCapabilities number of processor cores NumberOfProcessorCores For example: 1, 2, 4 number of hardware threads NumberOfHardwareThreads For example: 1, 2 HP_ProcessorCapabilities Value: 0 –if Intel VT Disabled VirtualizationTechnologyStatus 1 – if Intel VT Enabled SMX_ProcessorCapabilities 1-2-3 SMX_ProcessorCore Class The SMX_ProcessorCore class
Property Name Property Implementation Processor:
Core: ElementName Where: is the processor number and is the core number. CIM_ManagedSystemElement Processor: Core: Name Where: is the processor number and is the core number.
Property Name CoreEnabledState Property Implementation 2 (Core Enabled) For x86 processors: Characteristics[0]: 3 (32-bit Capable) Characteristics For x64 processors: Characteristics[0]: 3 (32-bit Capable) Characteristics[1]: 2 (64-bit Capable) HP_ProcessorCore FALSE Bootstrap TRUE SMX_ProcessorCore 1-2-4 SMX_HardwareThread Class The SMX_HardwareThread class extends the CIM_HardwareThread class to model the hardware threads. The following table lists the properties implemented.
Property Name Property Implementation 7) Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation HPQ:SMX_HardwareThread: Proc:
Core: Thread: InstanceID Where: is the processor number, is the core number and is the thread number HP_HardwareThread SMX_HardwareThread 1-2-5 SMX_CacheMemory Class The SMX_CacheMemory class implements the HP_CacheMemory class, which extends CIM_Memory to model the processor caches. The following table lists the properties implemented.
Property Name Property Implementation 0 (Unknown) 2 (OK), when CPU is enabled and operational OperationalStatus 5 (Predictive Failure), when IML error info logged for this CPU 6 (Error), when CPU is disabled via POST error 10 (Stopped), when CPU is disabled via RBSU StatusDescriptions[0] text per OperationalStatus[0]: Unknown StatusDescriptions OK Stopped Error Predictive Failure 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 15 (Minor Failure)
Property Name Property Implementation Proc
, Level Cache Where: is the processor number, is the cache level number, and is the cache type (Data, Instruction, or Unified) Proc , Core , Level Cache DeviceID Where: is the processor number, is the cache level number, and is the cache type (Data, Instruction, or Unified) For example: Proc 1, Level 1 Data Cache For example: Proc 1, Core 2, Level 2 Unified Cache CIM_StorageExtent BlockSize 1 – numbe
Property Name Property Implementation GroupComponent References SMX_ComputerSystem PartComponent References SMX_Processor 1-2-7 SMX_ProcessorElementCapabilities Class The SMX_ProcessorElementCapabilities class extends the CIM_ElementCapabilities class and associates SMX_Processor and SMX_ProcessorCapabilities instances. The following table lists the properties implemented.
1-2-9 SMX_HWThreadComponent Class The SMX_HWThreadComponent class extends the CIM_ConcreteComponent class and associates an SMX_ProcessorCore instance with SMX_HardwareThread instances. The following table lists the properties implemented.
Property Name Property Implementation 0 (Unknown) 1 (Other) WritePolicy 2 (Write Back) 3 (Write Through) 4 (Varies with Address) 5 (Determination Per I/O) 0 (Unknown) 1 (Other) CacheType 2 (Instruction) 3 (Data) 4 (Unified) LineSize Cache line size in bytes 0 (Unknown) 1 (Other) ReadPolicy 2 (Read) 3 (Read-Ahead) 4 (Read and Read-Ahead) 5 (Determination Per I/O) 0 (Unknown) 1 (Other) 2 (Direct Mapped) Associativity 3 (2-way Set-Associative) 4 (4-way Set-Associative) 5 (Fully Associative) 6 (8-way
Property Name Dependent 1-2-11 Property Implementation References SMX_Processor SMX_ProcessorCollection Class The SMX_ProcessorCollection class extends the HP_GroupSystemSpecificCollection class. The following table lists the properties implemented.
Property Name Property Implementation GroupStatusDescriptions[0] text per GroupOperationalStatus[0]: Unknown Other OK Degraded GroupStatusDescriptions Predicted Failure Failed Stopped The status descriptions of the processors that make up the overall operational status are contained in OperationalStatus[1-n]. See the descriptions for GroupStatusDescriptions for members of the processor collection for the list of possible values.
The following table lists the properties implemented. Property Name Property Implementation CIM_MemberOfCollection SMX_MemberOfProcessorCollection Member References SMX_Processor Collection References SMX_ProcessorCollection 1-2-14 SMX_ProcessorChip Class The SMX_ProcessorChip class extends the CIM_Chip class to model the physical processor chip. The following table lists the properties implemented.
Property Name Property Implementation 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 15 (Minor Failure), when OperationalStatus[0]=10 (Stopped) 20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure) 25 (Critical Failure), when OperationalStatus[0]=6 (Error) CIM_PhysicalElement Tag Where: is the processor manufacturing name, is the process
Property Name Property Implementation stepping number PoweredOn CanBeFRUed False – if CPU is disabled via RBSU or POST error True – if CPU is enabled True CIM_PhysicalComponent RemovalConditions 3 (Removable When Off) CIM_Chip HP_ProcessorChip Stepping ProcessorChipRevision Where: is the processor stepping number SMX_ProcessorChip 1-2-15 SMX_RealizesProcessor Class The SMX_RealizesProcessor class extends the CIM_Realizes class and associates SMX_Processor instances with SMX_ProcessorChip
1-2-16 SMX_SystemPhysicalProcessor Class The SMX_SystemPhysicalProcessor class extends the CIM_Container class and associates the SMX_ComputerSystemChassis instance with SMX_ProcessorChip instances. The following table lists the properties implemented.
Property Name Property Implementation ( Family Model Stepping ) Description Where : is the processor brand string, is the CPU architecture type, is the processor family number, is the processor model number and is the processor stepping number. For example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation If only socket number is available: LocationInformation[0]: Where: is the socket number If only slot number is available: LocationInformation LocationInformation[0]: Where: is the slot number If both socket and slot numbers are available: LocationInformation[0]: Where: is the socket number LocationInformation[1]: Where: is the slot number.
Property Name Property Implementation Element References SMX_ProcessorChip PhysicalLocation References SMX_ProcessorLocation Physical Location 1-3 The Processor Physical Location is a string representing the physical location of a physical CPU module or chip. This string should represent the physical location of the device with which an end-user can uniquely locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags.
Property Name Property Implementation IndicationIdentifier GUID string generated at the time of indication. IndicationTime Time of indication. CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown. SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses For example: 01.05.
Property Name PerceivedSeverity Property Implementation 4 (Minor) CIM_AlertIndication Description CPU Failed Power on Self Test (POST) AlertType 5 (Device Alert) EventID 1 EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replace the failed processor HP_AlertIndication Summary CPU Failed Power on Self Test (POST) ProbableCause 1 (Other) 1-4-3 HP_DeviceIndication: Processor Disabled by BIOS or EFI Property Name Property Implementation CIM_Indication PerceivedSever
Property Name ProbableCause Property Implementation 1 (Other) HP Insight Management WBEM CPU Provider Overview 28
1-4-4 HP_DeviceIndication: Processor Predicted to fail Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication Description CPU Predictive Failure Notification AlertType 5 (Device Alert) EventID 3 EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replace the failing processor.
1 HP Insight Manager WBEM Ethernet Description The HP Insight Management Web-Based Enterprise Management (WBEM) Ethernet Port provider implements and extends Common Information Model (CIM) classes described in this document to model the ethernet port. These classes reside in the local host OS CIM Object Manager (CIM OM) on each individual monitored system and describe the ethernet ports, associated controllers, and logical ethernet interfaces that are available in the system.
1-1 Setting Up the Provider Installing the Provider There are no special installation instructions for this provider. It is installed by default as part of the HP Insight Management WBEM providers. Configuring the Provider This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. 1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_EthernetPortControllerSoftwareIdentity • SMX_EthernetPortControllerFirmwareIdentity • SMX_EthernetElementSoftwareIdentity • SMX_EthernetElementFirmwareIdentity • SMX_EthernetCollection • SMX_EthernetMemberOfCollection • SMX_EthernetGroupHostedCollection • SMX_EthernetTeam, • SMX_EthermetTeamMember • SMX_HostedEthernetTeam • SMX_EthernetTeamToLANEndpoint • SMX_EthEventSettings The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation on a particular controller. For example: Ethernet port on ethernet controller . ElementName Same as Caption. CIM_ManagedSystemElement HealthState 5 (OK), 10 (Degraded), 20 (MajorFailure) The logical MAC address of the Ethernet Port, typically for the format FFFFFFFFFFFF Name Where: each is a text representation of a hexadecimal digit 0x0 - 0xF.
Property Name Property Implementation CreationClassName SMX_EthernetPort DeviceID HPQ:SMX_EthernetPort: SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem MaxSpeed Current bandwidth in bits per second if port has link (value is 0, otherwise). Typically one of the following: 10000000, 100000000, 1000000000, or 2500000000 CIM_NetworkPort AutoSense Boolean that is true if Ethernet Port can automatically determine speed of comm.
Property Name Property Implementation 1 (Other) 50 (10BaseT) 51 (10-100BaseT) 52 (100BaseT) 53 (1000BaseT) 54 (2500BaseT) 55 (10GBaseT) 56 (10Gbase-CX4) 100 (100Base-FX) 101 (100Base-SX) 102 (1000Base-SX) 103 (1000Base-LX) 104 (1000Base-CX) 105 (10GBase-SR) 106 (10GBase-SW) 107 (10GBbase-LX4) 108 (10GBase-LR) 109 (10GBase-LW) 110 (10GBase-ER) 111 (10GBase-EW) Array of 16 bit unsiged integers advertising the capabilities of the EthernetPort: Capabilities[] 0 (Unknown) 1 (Other) 2 (AlertOnLan) 3 (WakeOnLan
Property Name Property Implementation Alert On LAN Wake On LAN EnabledCapabilities[] Specifies which of the Ethernet Ports capabilities are enabled. NetworkAddresses[] Array of MAC addresses affiliated with port. Formatted like 001122334455 with no delimiting. HP_EthernetPort VirtualPortNumber Non-Zero Virtual Port Number for FlexNICs that are partitioned. Value is 0 for non-Flex NICs and FlexNICs that are not partitioned.
Property Name Property Implementation CIM_ManagedSystemElement 5 (OK), normal operation HealthState 20 (MajorFailure) Name Opaque key, of the format HPQ:SMX_EthernetLANEndpoint:instanceNumber 0 (Unknown) 2 (OK) OperationalStatus 3 (Degraded - indicating that there is no link for this port) 6 (Error - indicating a link that was active is now lost) StatusDescriptions[0] per OperationalStatus[0]: Unknown StatusDescriptions OK Degraded Error CIM_LogicalDevice CIM_EnabledLogicalElement CIM_ServiceAccessP
Property Name Property Implementation For example: LAN Endpoint(instanceNum) for: 82546GB Gigabit Ethernet Controller port portNumber ProtocolIFType 6 (Ethernet CSMA/CD) CIM_LANEndpoint Text representing the principal unicast address used in communication with the LAN Endpoint. Twelve hexadecimal digits.
Property Name Property Implementation CIM_Dependency CIM_DeviceSAPImplementation HP_EthernetPortToLANEndpoint Antecedent Reference to SMX_EthernetPort. Dependent Reference to SMX_EthernetLANEndpoint. 1-2-6 SMX_EthernetPortController Class The SMX_EthernetPortController class implements the HP_EthernetPortController class and is a logical device corresponding to a hardware Ethernet network controller. The following table lists the properties implemented.
Property Name Property Implementation StatusDescriptions Ethernet Controller status: OK CIM_LogicalDevice CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName SMX_EthernetPortController SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.
1-2-8 SMX_EthernetPortControllerPhysicalPackage Class The SMX_EthernetPortControllerPhysicalPackage class implements the HP_EthernetPortControllerPhysicalPackage class and describes an Ethernet Port Controller Physical Package.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Product name.
Property Name Property Implementation Hardware version of the Package or N/A Version CIM_PhysicalPackage If PackageType package.
Property Name Property Implementation CIM_ManagedElement Product Name. ElementName For Example: 2 port controller: Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21) Description Value of ElementLocationTag prefaced with either “Embedded Controller” or “Ethernet Controller in” Caption Same as Description. CIM_Location Name PCISLOT or EMBEDDED ETHERNET Opaque key.
Property Name Property Implementation 7 (Cabinet) 6 (Chassis) Additional enumerators 14 (Blade) for HP BladeSystem 1 (Mezzanine) servers Array of text values representing the location components that describe this Ethernet Controller Physical location. LocationInformation LocationInfoDesc[0] per LocationInfornation[0]. Refer to the LocationInfoDescription array to determine what type of location information is represented.
Property Name Value information. For example: IP Protocol Endpoint (instanceNum) for: port 82546GB Gigabit Ethernet Controller For ESXi, IP Protocol Endpoint information for management network logical interface name. For example: IP protocol Endpoint for vmk0-ipv4-0 Caption Same as associated ElementName Operating System ethernet device name. Description For example: eth1 For ESXi, management network logical interface name.
Property Name Value CIM_ProtocolEndpoint 0 (Unknown) 2 (OK) OperationalStatus 3 (Degraded) 6 (Error) CIM_IPProtocolEndpoint How the Address was assigned to this IP Protocol Endpoint. 0 (Unknown) AddressOrigin 3 (Static) 4 (DHCP) IPv4Address Only initialized if IP interface advertises a valid IPv4 Address. IPv6Address Only initialized if IP interface advertises a valid IPv6 Address. If ProtocolIFType is 4097 or 4098, then this property will be implemented.
Property Name Value HPQ:SMX_IPProtocolEndpoint: concatenated with the class instance id number. 1 (Other) 4096 (IPv4) ProtocolIFType 4097 (IPv6) 4098 (IPv4/IPv6) SubnetMask Text representing the mask of the IPv4 address, if defined; otherwise, 0.0.0.
Property Name Property Implementation CIM_HostedDependency CIM_HostedAccessPoint HP_EthIPHostedAccessPont Antecedent Reference to SMX_ComputerSystem Dependent Reference to SMX_IPProtocolEndpoint 1-2-15 SMX_EthernetRemoteServiceAccessPoint Class The SMX_EthernetRemoteServiceAccessPoint class implements the HP_RemoteServiceAccessPoint class and describes the managed systems view of the default gateway. NOTE: Currently not implemented on on VMware ESXi platform.
Property Name SystemName Property Implementation SMX_ComputerSystem.Name CIM_RemoteServiceAccessPoint 0 (Unknown) AccessContext 2 (Default Gateway) If ProtocolIFType = 4095 (IPv4), then text value will be dotdelimited IP address of default gateway followed by the IPv4 netmask; otherwise, 0.0.0.0 if the default gateway is unassigned. AccessInfo If ProtocolIFType = 4097 or 4098 (IPv6), the text value will be either a valid IPv6 Address or ::/128if default gateway is unassigned.
Property Name Dependent 1-2-17 Property Implementation Reference to SMX_IPProtocolEndpoint SMX_EthernetRemoteServiceHostedAccessPoint Class The SMX_EthernetRemoteServiceHostedAccessPoint class implements the HP_RemoteServiceHostedAccessPoint class and associates the Remote Service Access Point to the Computer System in a managed system. NOTE: Currently not implemented on on VMware ESXi platform. The following table lists the properties implemented.
Property Name Property Implementation InstanceId HPQ:SMX_EthernetStatistics: SampleInterval 00000000000000.000000:000 StatisticTime Time of current statistics CIM_NetworkPortStatistics BytesReceived Total number of bytes received BytesTransmitted Total number of bytes transmitted PacketsReceived Total number of packets received CIM_EthernetPortStatistics AlignmentErrors See CIM_EthernetPortStatistics mof. DeferredTransmissions See CIM_EthernetPortStatistics mof.
Property Name Property Implementation HP_EthernetPortStatisticalData 1-2-20 SMX_EthernetPortControllerSoftwareIdentity SMX_EthernetPortControllerSoftwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter driver software of the associated Ethernet Port. Property Name Property Implementation CIM_ManagedElement Caption Ethernet Port Controller Driver Description Device Driver Where: is the product name of the Ethernet Adapter.
Property Name Description Property Implementation Ethernet Port Controler Firmware details for Where: is the Model name of the Ethernet Adapter. ElementName PCI Vendor Id: Device Id CIM_ManagedSystemElement Ethernet Port Controler Firmware details for Name Where: is the Model name of the Ethernet Adapter.
Property Name Property Implementation Antecedent ref:SMX_EthernetPortControllerSoftwareIdentity Dependent ref:SMX_EthernetPortController CIM_ElementSoftwareIdentity ElementSoftwareStatus 1-2-23 ElementSoftwareStatus[0]: ElementSoftwareStatus[1]: 2 (Current) 6 (Installed) SMX_EthernetElementFirmwareIdentity SMX_EthernetElementFirmwareIdentity implements the class CIM_ElementSoftwareIdentity.
Property Name Property Implementation CIM_SystemSpecificCollection InstanceID HPQ:SMX_EthernetCollection-1 HP_GroupSystemSpecificCollection GroupOperationalStatus 0 (Unknown) 2 (OK) 3 (Degraded) 6 (Error) GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: Unknown OK Degraded Error HP_EthernetCollection 1-2-25 SMX_EthernetMemberOfCollection SMX_EthernetMemberOfCollection associates Ethernet Ports to the Ethernet Collection.
Property Name Property Implementation CIM_Dependency Antecedent ref:SMX_ComputerSystem Dependent ref:SMX_EthernetCollection CIM_HostedDependency CIM_HostedCollection HP_EthernetGroupHostedCollection 1-2-27 SMX_EthernetTeam SMX_EthernetTeam models Ethernet Redundancy Sets (Ethernet Teams). NOTE: Currently not implemented on on VMware ESXi platform.
Property Name MinNumberNeeded OtherLoadBalanceAlgorithm Property Implementation 1 When LoadBalanceAlgorithm is 1 (Other), OtherLoadBalanceAlgorithm is set to configured Load Balance Algorithm. For example: Automatic RedundancyStatus 2 (Fully Redundant) 3 (Degraded Redundancy) 4 (Redundancy Lost) 5 (Overall Failure). TypeOfSet 2 (N+1) 3 (Load Balanced).
NOTE: Currently not implemented on on VMware ESXi platform. Property Name Property Implementation CIM_MemberOfCollection Key:Collection ref:HP_EthernetTeam Key:Member ref:HP_EthernetPort HP_EthernetTeamMember MemberOperationalStatus 2 (OK) 3 (Degraded) 6 (Error) MemberStatusDescriptions Refer to HP Ethernet Teaming Profile.
Property Name Property Implementation CIM_ Dependency Key:OwnedElement ref:HP_EthernetTeam Key:OwningElement ref:HP_ComputerSystem HP_ EthernetTeamToLANEndpoint 1-2-31 SMX_EthEventSetting SMX_EthEventSettings models configurable Ethernet Indication settings. NOTE: Currently not implemented on on VMware ESXi platform.
Property Name Property Implementation MemberLeftTeam If enabled, an event is generated when an adapter leaves a team. Default, disabled. MemberRoleChanged If enabled, an event is generated when any change in team member role is detected. Default, disabled. MemberStatusChanged If enabled, an event is generated when any change in team member status is detected. Default, disabled. MonitorLANEndpoints If enabled, events related to SMX_EthernetLANEndpoint are generated. Default, disabled.
Property Name Property Implementation On ESX, 39 (VM) OSType On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name EventSubCategory Property Implementation 11 (Ethernet port) 12 (Ethernet team) 13 (Ethernet LAN Endpoint) ProbableCause 7 (Communications Subsystem Failure) ProbableCauseDescription Network Interface Lost Connectivity HP_AlertIndication: Network Interface Connectivity Restored 1-3-2 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description If the Network Interface is an Ethernet Port, the Ethernet Port has transitioned fr
HP_AlertIndication: Group System Specific Consolidated Status Policy Change 1-3-3 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Informational) CIM_Alertindication Description HP_GroupSystemSpecificConsolidated operational status policy has been modified to monitor operational status from different set of managed elements.
Property Name PerceivedSeverity Property Implementation 6 (Critical) CIM_Alertindication Description An Ethernet team's redundancy status changed to Redundancy Lost. All members of an Ethernet team, except one, are failed. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting lost redundancy AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 5 ProviderName HP Ethernet RecommendedActions Check the Ethernet Team and Ethernet Team Member status.
Property Name Property Implementation ProviderName HP Ethernet RecommendedActions No action is recommended HP_AlertIndication Summary Ethernet team redundancy increased EventCategory 9 (Network Device) EventSubCategory 12 (Ethernet team)) ProbableCause 1 (Other) ProbableCauseDescription Ethernet Team Redundancy Increased 1-3-6 HP_AlertIndication: Ethernet Team Redundancy Decreased Property Name Property Implementation CIM_Indication PerceivedSeverity 3 (Warning) CIM_Alertindication Desc
1-3-7 HP_AlertIndication: Ethernet Team Redundancy Restored Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description An Ethernet team's redundancy status changed to Fully Redundant. An Ethernet team member status changed from Error or Degraded to OK. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting full redundancy restored.
Property Name Property Implementation status change. AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 10 ProviderName HP Ethernet RecommendedActions Check the Ethernet Team and Ethernet Team Member status. View the System Event Log for additional information.
Property Name Property Implementation Summary Ethernet Team Member Reported Role Change.
Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description A new team member has been added to an Ethernet team via the HP Network Configuration Utility (NCU). This is an optional indication that can be disabled via the Ethernet Event Provider settings. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting lost redundancy.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 12 ProviderName HP Ethernet RecommendedActions Ensure the network interface was made unavailable intentionally.
Property Name Property Implementation EventSubCategory 12 (Ethernet team) ProbableCause 1 (Other) ProbableCauseDescription New Network Interface Available HP_AlertIndication: Ethernet Team Active Member Count Change 1-3-14 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description The number of active adapters in an Ethernet team has changed. This is an optional indication that can be disabled via the Ethernet Event Provider settings.
1-4 Physical Location The Ethernet Port Physical Location is a string representing the physical location of the Ethernet Port. This string should represent the physical location of the device with which an end-user can uniquely locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags. The following table lists the properties implemented. Any combination of the following applicable descriptors could be used to better define the device location.
1 HP Insight Manager WBEM Fibre Channel Host Bus Adapter Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Fibre Channel Host Bus Adapter Profile describes the behavior of Fibre Channel host adapters supporting the SCSI (Fibre Channel Protocol) command set. A Fibre Channel (FC) adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports. A single system can contain one or more HBAs.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_FCHBASystemPackaging • SMX_FCHBAGroupHostedCollection • SMX_FCHBAFCPortGroupSystemSpecific • SMX_FCHBALocation • SMX_FCHBAPhysicalElementLocation The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_Systems CreationClassName SMX_FCHBAComputerSystem NameFormat Other CIM_ComputerSystem Dedicated 0 IdentifyingDescriptions[0] HPQ:GUID OtherIdentifyingInfo[0] GUID 1-2-2 SMX_FCHBAFCPort Class The SMX_FCHBAFCPort class implements the HPFCHBA_FCPort class is used to represent a FC port device. The following table lists the properties implemented.
Property Name Value Unknown OK-Online Stopped Offline StatusDescriptions[0] Stopped Bypassed Stopped Diagnostics Stopped Link down Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBAFCPort DeviceID Opaque value. SystemName Opaque value.
Property Name Value Other Not present Fabric Public Loop FL Port OtherPortType Fabric Port Fabric expansion port Generic Fabric Port Private Loop Point to Point PortType 1 (Other) Typically one of the following (in Bits per Second): 0 1000000000 Speed 2000000000 10000000000 UsageRestriction 4 (not restricted) CIM_NetworkPort LinkTechnology 4 (FC) PermanentAddress Port WWN PortNumber Port number. SupportedMaximumTransmissionUnit Port maximum frame size.
Property Name Value CIM_ManagedSystemElement NodeWWN Name CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBAPortController Node WWN:SerialNumber: DeviceID Where: is the port controller instance number for the same adapter.
Property Name SampleInterval Value 00000000000000.000000:000 CIM_NetworkPortStatistics BytesTransmitted HBAAPI_PORTSTATISTICS.TxWords BytesReceived HBAAPI_PORTSTATISTICS.RxWords PacketsTransmitted HBAAPI_PORTSTATISTICS.TxFrames PacketsReceived HBAAPI_PORTSTATISTICS.RxFrames CIM_FCPortStatistics CRCErrors HBAAPI_PORTSTATISTICS.InvalidCRCCount DumpedFrames HBAAPI_PORTSTATISTICS.DumpedFrames ErrorFrames HBAAPI_PORTSTATISTICS.ErrorFrames InvalidTransmissionWords HBAAPI_PORTSTATISTICS.
The following table lists the properties implemented. Property Name Value CIM_ManagedElement Description Grouping of all FC Ports for this HBA Caption Logical Port Group ElementName Logical Port Group CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque CIM_LogicalPortGroup Name NodeWWN NameFormat WWN 1-2-6 SMX_FCHBAPhysicalPackage Class The SMX_FCHBAPhysicalPackage class represents the physical elements of the associated FC port controller.
Property Name Value CreationClassName SMX_FCHBAPhysicalPackage Manufacturer Manufacturer Model Model Location; PCI Slot OtherIdentifyingInfo Where: is the PCI slot number OR PCI Mezzanine= where is the Mexannine slot number.
1-2-8 SMX_FCHBASoftwareIdentityDrv Class The SMX_FCHBASoftwareIdentityDrv class represents adapter software associated with the FC port controller. The following table lists the properties implemented. Property Name Value CIM_ManagedElement Caption FCHBA Driver Device Driver Description ElementName Where: is the product name of the HBA.
Property Name Description ElementName Value FCHBA Firmware details for Where: is the model name of the HBA.
Property Name Value NodeWWN Name CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FCHBA Option ROM Classifications 11 (bios/fc) HPQ:NodeWWN: InstanceID Where: is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString BIOS Version as reported by HBA TargetTypes HBA BIOS UNKNOWN SerialNumber Serial Number MajorVersion 0 MinorVersion 0 RevisionNumber 0 HP_SoftwareIdentity 1-2-11 SMX_FCHBAGroupSystemSp
Property Name Value CIM_SystemSpecificCollection Opaque InstanceID HP_GroupSystemSpecificCollection 0 (Unknown) 1 (Other) GroupOperationalStatus[0] 2 (OK) 3 (Degraded) 6 (Error) 10 (Stopped) Unknown Other OK GroupStatusDescriptions[0] Degraded Error Stopped 1-2-12 SMX_FCHBAComputerSystemFCPort Class The SMX_FCHBAComputerSystemFCPort class is used to represent an association between SMX_ComputerSystem and HPFCHBA_FCPort. The following table lists the properties implemented.
Property Name Value CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemPortController GroupComponent Refer to SMX_FCHBAComputerSystem class properties. PartComponent Refer to SMX_FCHBAPortController class properties. 1-2-14 SMX_FCHBAPortControllerPCIDevice Class The SMX_FCHBAPortControllerPCIDevice class is used to represent an association between SMX_PCIDevice and SMX_FCHBAPortController. The following table lists the properties implemented.
1-2-16 SMX_FCHBAComputerSystemSoftwareIdentityDrv Class The SMX_FCHBAComputerSystemSoftwareIdentityDrv class is used to represent an association between SMX_ComputerSystem and SMX_FCHBASoftwareIdentityDrv. The following table lists the properties implemented. Property Name Value CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemSoftwareIdentityDrv InstalledSoftware Refer to SMX_FCHBASoftwareIdentityDrv class properties. System Refer to SMX_FCHBAComputerSystem class properties.
Refer to SMX_FCHBAFCPort class properties. Member 1-2-19 SMX_FCHBAPortControllerFCPort Class The SMX_FCHBAPortControllerFCPort is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFCPort. The following table lists the properties implemented. Property Name Value CIM_Dependency CIM_ControlledBy SMX_FCHBAPortControllerFCPort Antecedent Refer to SMX_FCHBAPortController class properties. Dependent Refer to SMX_FCHBAFCPort class properties.
CIM_ElementSoftwareIdentity SMX_FCHBASoftwareIdentityDrvPortController Antecedent Refer to SMX_FCHBASoftwareIdentityDrv class properties. Dependent Refer to SMX_FCHBAPortController class properties. 1-2-22 SMX_FCHBAPortControllerFirmwareIdentityFW Class The SMX_FCHBAPortControllerFirmwareIdentityFW class is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFirmwareIdentityFW. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Value CIM_Component CIM_ProductPhysicalComponent SMX_FCHBAProductPhysicalComponent GroupComponent Refer to SMX_FCHBAProduct class properties. PartComponent Refer to SMX_FCHBAPhysicalPackage class properties. 1-2-25 SMX_FCHBASystemPackaging Class The SMX_FCHBASystemPackaging class is used to represent an association between SMX_FCHBAPhysicalPackage and SMX_ComputerSystem. The following table lists the properties implemented.
Antecedent Refer to SMX_ComputerSystem class properties. Dependent Refer to SMX_FCHBAGroupSystemSpecificCollection class properties. 1-2-27 SMX_FCHBAFCPortGroupSystemSpecific Class The SMX_FCHBAFCPortGroupSystemSpecific class is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAGroupSystemSpecificCollection. The following table lists the properties implemented.
1-2-29 SMX_FCHBAPhysicalElementLocation Class The SMX_FCHBAPhysicalElementLocation is used to represent an association between the SMX_FCHBAPhysicalPackage and SMX_FCHBALocation. The following table lists the properties implemented. Property Name Value CIM_ElementLocation SMX_FCHBAPhysicalElementLocation Element Refer to SMX_FCHBAPhysicalPackage class properties. PhysicalLocation Refer to SMX_FCHBALocation class properties.
Property Name Value DeviceID PortWWN SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolController MaxUnitsControlled 255 CIM_SCSIProtocolController 1-2-31 SMX_FCHBASCSIProtocolEndpoint SMX_FCHBASCSIProtocolEndpoint represents a SCSI protocol controller running through a part.
1-2-32 SMX_FCHBAComputerSystemSCSIProtocolController SMX_FCHBAComputerSystemSCSIProtocolController is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolController.
Property Name Dependent 1-2-35 Value ref:SMX_FCHBAFCPort SMX_FCHBASystemServiceAccessPoint SMX_FCHBASystremServiceAccessPoint is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolEndpoint.
All Systems HP Integrity Cellular Servers HP BladeServers in C3000 / C7000 Enclosures PCI Slot= Cabinet= Blade= Embedded Controller= Bay= RootPort= (if embedded on System Board) System Mainboard (referring to System Board/motherboard) Chassis= Mezzanine= (I/O Mezzanine slot num) 1-4 Provider Indications Indications Generated by the Provider This provider generates no indications.
1 HP Insight Manager WBEM Host File System Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Host Filesystem provider and extends CIM classes described in this document to model the filesystems hosted by a managed node. These classes provide computational information and capabilities that serve as an aggregation point to associate one or more elements that make up hosted filesystems and logical disks.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_LocalFileSystem • SMX_HostedLocalFileSystem • SMX_LocalLogicalDisk • SMX_LocalFSResidesOnExtent The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation OS path name to filesystem root location. Root For example: /home/users AvailableSpace Total amount of free space for the filesystem in bytes. Unknown = 0. BlockSize Read/write data block size in bytes. FileSystemSize Total size of the filesystem in bytes. Unknown = 0. String describing the type of filesystem.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement CIM_LogicalDevice SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName CreationClassName SMX_LocalLogicalDisk Path to logical disk. DeviceID For example: /dev/cdrom1 CIM_StorageExtent BlockSize Read/write data block size in bytes.
1-2-4 SMX_LocalFSResidesOnExtent Class The SMX_LocalFSResidesOnExtent class implements the CIM_ResidesOnExtent class and associates the SMX_LocalFileSystem and SMX_LocalLogicalDisk instances. The following table lists the properties implemented.
1 HP Insight Management WBEM IML Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Integrated Management Log (IML) provider implements the server management record log. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Record Log Profile (P00109) HP WBEM TC 1.1.
• SMX_IMLUseOfLog The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation. When the Property Implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis.
Property Name Property Implementation 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 10 (Degraded), when OperationalStatus[0]=3 (Degraded) 20 (Major Failure), when OperationalStatus[0]=6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 5 (No Change) EnabledDefault 2 (Enabled) CIM_Log MaxNumberOfRecords 0 (Indicates variable length records.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement IML record log entry Caption Where: is the SMX_IMLLogEntry.RecordID for the event. Description Description based on specific IML log event. IML record log entry ElementName Where: RecordID is the SMX_IMLLogEntry.RecordID for the event. CIM_RecordForLog CIM_LogEntry HPQ:SMX_IMLLogEntry: InstanceID Where: is the IML event number.
Property Name Property Implementation 0 (Unknown) 36 (Linux) OSType 39 (VMware) SystemSerialNumber System serial number string from SMBIOS. SystemProductID System product ID string from SMBIOS. SystemModel System model number string from SMBIOS. SystemName Computer system name 0 (Unknown) VendorID 3 (HP) 5 (Compaq) 0 (Unknown) ServerHardwareArchitecture 7 (x86-32) 10 (x86-64) LoggerType 2 (Server) The following table lists the methods implemented for the SMX_IMLLogEntry class.
1-2-4 SMX_IMLUseOfLog Class The SMX_IMLUseOfLog class implements the HP_UseOfLog class and associates the instance of SMX_ComputerSystem with the instance of SMX_IMLRecordLog. The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_UseOfLog HP_UseOfLog Antecedent References SMX_IMLRecordLog Dependent References SMX_ComputerSystem 1-3 Supported indications There are no indications specific to the profile registration implementation.
1 HP Insight Management WBEM IPMI Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Intelligent Platform Management Interface (IPMI) Record Log provider supports system logs available on HP servers. These logs are called the System Event Log (SEL) and the Forward Progress Log (FPL) and contain informational, warning, and critical event information about a server’s performance and sensors.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_FPLRecordLog • SMX_FPLLogEntry • SMX_FPLLogManagesRecord • SMX_FPLUseOfLog • SMX_SELRecordLog • SMX_SELLogEntry • SMX_SELLogManagesRecord • SMX_SELRecordLogIndication • SMX_SELUseOfLog The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation Description Forward Progress Log ElementName FPL record log CIM_ManagedSystemElement Name FPL record log OperationalStatus OperationalStatus[0] indicates whether the FPL log is in good health and accepting new FPL entries.
Property Name TimeOfLastChange Property Implementation Time of last log change The following table lists implemented methods for the SMX_FPLRecordLog class. Method Name Method Implementation ClearLog See the HP Record Log profile. RepairAll See the HP Record Log profile. 1-2-2 SMX_FPLLogEntry Class The SMX_FPLLogEntry class implements the HP_CommonLogEntry class to model logs records within the FPL log. The following table lists the properties implemented.
Property Name Property Implementation System serial number string from SMBIOS. SystemSerialNumber For example: USE4822L0H System model number string from SMBIOS. SystemModel For example: server rx6600 SystemName Computer system name. LoggerType 2 (Server) The following table lists implemented methods for the SMX_FPLLogEntry class. Method Name See the HP Record Log profile.
The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_UseOfLog HP_UseOfLog Antecedent References SMX_FPLRecordLog Dependent References SMX_ComputerSystem 1-2-5 SMX_SELRecordLog Class The SMX_SELRecordLog class implements the HP_CommonRecordLog class to model the server management record log. The following table lists the properties implemented.
Property Name Property Implementation EnabledState 2 (Enabled) RequestedState 5 (Not Applicable) EnabledDefault 2 (Enabled) CIM_Log MaxNumberOfRecords Number of records available in NVRAM. This will be greater than 0 Number of records in the SEL log (not equal to the SMX_SELLogEntry CurrentNumberOfRecords instances as these instances are the sum of both SEL log entries and the SEL cache).
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement SEL record log entry Caption Where: RecordID is the SMX_SELLogEntry.RecordID for the event. Description Same as Caption. ElementName Same as Caption. CIM_RecordForLog CIM_LogEntry InstanceID HPQ: LogInstanceID SMX_SELRecordLog.InstanceID LogName SMX_SELRecordLog.Name RecordID SEL event number.
The following table lists implemented methods for the SMX_SELLogEntry class. Method Name See the HP Record Log Profile. Repair 1-2-7 Method Implementation SMX_SELLogManagesRecord Class The SMX_SELLogManagesRecord class implements the HP_LogManagesRecord class and associates instances of HP_RecordLog and HP_LogEntry. The following table lists the properties implemented.
1-3 Provider Indications 1-3-1 SMX_SELRecordLogIndication Class The SMX_SELRecordLogIndication class implements and extends the HP_CommonRecordLogIndication class to Alert Clients to to new WBEM events found in the SEL Record log.
Property Name Property Implementation OSType On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: , , ProbableCause 0 (Unknown) ProbableCauseDescription Short text describing cause if known. RecommendedActions If action exists, this array will contain text values of human readable strings for potential resolution. Summary Short Text describing the SEL Record Log Event.
Property Name LogEntryInstanceIDs Property Implementation Array of length 1 containing an opaque Log Entry key. SMX_SELRecordLogIndication RawData Array if 14 bytes of raw event data.
1 HP Insight Management WBEM Management Processor Lite Provider The HP Insight Management Web-Based Enterprise Management (WBEM) Management Processor Lite provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Management Processor (MP) Lite Profile HP WBEM TC 2.1.
Schema Supported by the Provider This provider supports the following classes: • SMX_ManagementProcessor • SMX_MPFirmware • SMX_MPCollection • SMX_MPHostedCollection • SMX_MPComponentCS • SMX_MPMemberOfCollection • SMX_MPElementFirmwareIdentity • SMX_MPInstalledFirmwareIdentity • SMX_MPConsolidatedStatusView • SMX_MPScopedConsolidatedStatusView • SMX_ManagementController • SMX_MPControllerMP • SMX_MPControllerPCIDevice The tables in the following sections describe the properties o
Property Name Property Implementation Short Description of the Management Processor, including the product name and the enabled state of the MP. For example: Product name of the management processor in the format: (X) Where: is the name of the MP product and (X) indicates whether the MP is Active or Inactive/Disabled.
Property Name Property Implementation Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor Lite Profile for specific descriptions of when each value is populated).
Property Name Property Implementation utilizing host NIC 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), normal operation 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) 20 (Major failure), when OperationalStatus[0]=6 (Error) HealthState Note: When a Management Processor is disabled (refer to property EnabledState) HealthState will always report a state of 5 (OK) so as not to contribute negatively to overall system status.
Property Name Property Implementation CIM_System CreationClassName SMX_ManagementProcessor Name Opaque instance identifier using HPQ as the OrgID. For example: HPQ:SMX_ManagementProcessor:1 CIM_ComputerSystem Dedicated 14 (Management) ResetCapability 4 (Enabled) HP_ManagementProcessor Enumerator indicating the model or type of management processor.
Property Name Property Implementation The IP address of the MP-resident network interface. Note: IPAddress When a Management Processor is disabled (refer to property EnabledState) IP Address will always be reported as 0.0.0.0. Network communication with the MP is not possible when the MP is disabled. The Uniform Resource Locator of the management processor controller’s webbased user interface.
Property Name Property Implementation Enumerator indicating the license type of the Management Processor. 0 (Unknown) 1 (None) 2 (iLO Advanced) ActiveLicense 3 (iLO Light) 4 (iLO Advanced for Blade System) 5 (iLO standard for Blade System) Note: When communication failure with MP occurs then ActiveLicense is Unknown. If no license present then ActiveLicense is None.
Property Name Property Implementation For example: Management Processor Firmware Description Description of the MP firmware. For example: HP Management Processor Firmware Represents the target type/firmware family. Examples: ElementName RI7 for iLO 2 RI9 for iLO 3 RI10 for iLO 4 Lights Out 100 (LO100) CIM_ManagedSystemElement Product name of the management processor.
Property Name Classifications Property Implementation 10 (Firmware) ClassificationDescriptions HP Management Processor Firmware Indexed array that provides the values described by the type information stored in the corresponding component of the IdentityInfoType array.
Property Name Property Implementation CIM_Collection CIM_SystemSpecificCollection Opaque instance identifier using HPQ as the OrgID. InstanceID For example: HPQ:SMX_MPCollection:1 HP_GroupSystemSpecificCollection Caption Caption for the class, for example: Management Processor Collection Describes the group operational status of the management processor collection (refer to HP Management Processor Lite Profile).
CIM_HostedCollection HP_GroupHostedCollection HP_MPHostedCollection Antecedent References SMX_ComputerSystem Dependent References SMX_MPCollection 1-2-5 SMX_MPComponentCS Class The SMX_MPComponentCS class implements the HP_MPComponentCS class to associate a management processor subsystem to the scoping computer system that contains it. The following table lists the properties implemented.
References SMX_ManagementProcessor Member 1-2-7 SMX_MPElementFirmwareIdentity Class The SMX_MPElementFirmwareIdentity class implements the HP_MPElementFirmwareIdentity class to associate a management processor to its corresponding firmware. The following table lists the properties implemented.
implemented, there shall be one instance of HP_ConsolidatedStatusView for each instance of HP_GroupSystemSpecificCollection. Property Name Property Implementation CIM_ManagedElement Unique name that describes this consolidated status view class instance collection represents.
Antecedent References HP_ComputerSystem Dependent References SMX_MPConsolidatedStatusView 1-2-11 SMX_ManagementController Class The SMX_ManagementController class implements the HP_ManagementController to describe a management controller. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Short Description of the Management Controller, including the product name and the enabled state of the MP.
Property Name Property Implementation Name of the Management Controller, including the product name and the enabled state of the MP. For example: Product name of the management processor controller in format: (X) Where: is the name of the MP product.
Property Name Property Implementation Descriptive text per OperationalStatus.
Property Name Property Implementation CIM_LogicalDevice CreationClassName SMX_ManagementController SystemCreationClassName SMX_ComputerSystem SystemName Value of SMX_ComputerSystem.
1-3 Provider Indications Indications Generated by the Provider 1-3-1 The following tables describe the SMX WBEM MP Provider indications that are implemented for HP Consolidated Status View. Provider Indication Common Properties Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication. IndicationTime Time of indication. CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown.
Property Name Property Implementation SystemGUID Platform GUID of the computer system generating the indication. SystemVirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. SystemVirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v.
Property Name Property Implementation instance AlertingElementFormat 2 (CIMObjectPath) AlertType 7 (Model Alert) EventID “1” ProviderName “HP MP” RecommendedActions “Inspect property arrays MemberObjectPaths and MemberStatusIncluded to discover new managed elements and whether each managed element status is included in collection operational status.
Property Name Property Implementation Description Consolidated View Class Collection operational status has transitioned to OK or participating members in the HP_GroupSystemSpeciticCollection have transitioned to OK. AlertingManagedElement CIM Object Path of the HP_ConsolidatedStatusView instance if implemented. Otherwise CIM Object Path of the HP_GroupSystemSpecificCollection.
Property Name PerceivedSeverity Property Implementation 3 (Degraded) CIM_AlertIndication Description Consolidated View Class Collection operational status has transitioned to Degraded or participating members in the HP_GroupSystemSpeciticCollection are now Degraded or Failed. AlertingManagedElement CIM Object Path of the HP_ConsolidatedStatusView instance if implemented. Otherwise CIM Object Path of the HP_GroupSystemSpecificCollection..
Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description Consolidated View Class Collection operational status has transitioned to error. AlertingManagedElement CIM Object Path of the HP_ConsolidatedStatusView instance if implemented. Otherwise CIM Object Path of the HP_GroupSystemSpecificCollection.
1 HP Insight Management WBEM PCI Device Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) PCI Device provider implements the profiles listed to support PCI devices installed on HP servers. The following table details the profiles implemented and files installed by this provider. Implemented Profiles 1-1 • DMTF: PCI Device Profile (DSP1075) 1.0.0a 09/2007 • DMTF: Physical Asset Profile • HP: Location Profile 1.2.
Property Name Property Implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_PCIController CIM_PCIDevice Capabilities Contains the capabilities of the PCI device.13 (PCI Express device) 5 (PCI-X capable device) CapabilityDescriptions Descriptions of capabilities. ClassCode Register of 8 bits that identify the basic function of the PCI device.
Property Name Property Implementation interpreted based on the value of the ClassCode byte.
Property Name PoweredOn Property Implementation True – if slot is powered on False – if slot is not powered CIM_PhysicalConnector ConnectorLayout 7 (Slot) ConnectorPinout “PCI” – if 33 MHz PCI slot “PCI-66” – if 66 MHz PCI slot “PCI-X” – if PCI-X slot “PCI Express” – if PCI Express slot “PCI Express Mezzanine” – if in-blade Mezzanine slot ConnectorType 43 (PCI) – if this is a 33 MHz PCI slot 80 (PCI-66MHZ) – if this is a 66 MHz PCI slot 98 (PCI-X) – if this is a PCI-X slot 1 (Other) – if this is a PC
Property Name Property Implementation Antecedent References SMX_PCICard Dependent References SMX_PCIDevice 1-2-6 SMX_SystemPCISlot Property Name Property Implementation GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_PCISlot 1-2-7 SMX_SystemPCIDevice Property Name Property Implementation GroupComponent References SMX_ComputerSystem PartComponent References SMX_PCIDevice 1-2-8 SMX_PCISlotLocation Property Name Property Implementation CIM_ManagedElement
Array of numerical enumerators describing values at comparable index in the LocationInformation array index 1,2, 3, or 4. LocationInfoDesc[0] per LocationInformation[0] 3 (PCI Slot). LocationInfoDesc Additional enumerators for Cellular servers 7 (Cabinet) 6 (Chassis) Additional enumerators for HP BladeSystem servers 14 (Blade) 1 (Mezzanine) LocationInformation 1-2-9 Array of text values representing the location components that describe this PCI Slot location.
All Systems HP Integrity Cellular Servers HP BladeServers in C3000 / C7000 Enclosures Slot= Cabinet= Blade= Embedded Controller= Bay= RootPort= (if embedded on System Board) Mezzanine= Chassis= Mezzanine= (I/O Mezzanine slot num) 1-4 Provider Indications Indications Generated by the Provider This provider generates no indications.
1 HP Insight Management Power Supply Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) Power Supply provider implements the HP Power Supply profile to model power supplies in servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Power Supply Profile HP WBEM TC 1.3 (P103) HP Location Profile HP WBEM TC 1.2.0 (P124) HP Power Supply Physical Asset Profile HP WBEM TC 1.0.
Insight Management WBEM support. 1-2 Using the Provider Namespaces Supported by the Provider Schema Supported by the Provider This provider returns instances in the root/hpq namespace.
behavior and the Managed Object Format interpretation is within parenthesis. If other values are returned, a problem is indicated. Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity (cellular and non-cellular) systems. The location related properties and implementation values are determined based on the server type so they may differ. 1-2-1 SMX_PowerSupply Class The SMX_PowerSupply class is used to model power supplies on servers.
Property Name Property Implementation Description of the status of the power supply corresponding to the OperationalStatus. StatusDescriptions[0] For example: Power Supply is operating properly– if OperationalStatus[0] is 2 (OK); Power Supply is degraded – if OperationalStatus[0] is 3 (Degraded) Power Supply has failed – if OperationalStatus is 6 (Error) StatusDescriptions[1] Description of the extended warning/error status corresponding to the OperationalStatus[1]. See Profile.
Property Name Property Implementation HP_PowerSupply PowerSupplyType Enumeration describing the type of power supply. Refer to the Managed Object Format. 1-2-2 SMX_PowerCollection Class The SMX_PowerCollection class is used to model power supply collections on servers. There is one instance of this class on servers modeling power supplies. The following table lists the properties implemented.
Property Name Property Implementation Represents the most severe power redundancy status and non-fault tolerant power supply operational status: 0 (Unknown) – if power collection status is unknown; 2 (OK) – if power supplies are operating properly; GroupOperationalStatus[0] 3 (Degraded) – if no SMX_PowerSupply.OperationalStatus[0] for all non-fault tolerant power supplies report 6 (Error) and SMX_PowerRedundancySet.
Property Name Property Implementation For example: Power Redundancy Set is collection of fault tolerant power supplies that provide redundant power Where: represents the number of the redundancy set instance. User printable name for this power redundancy set. ElementName For example: Power Redundancy Set Where: represents the number of the redundancy set instance. CIM_SystemSpecificCollection InstanceID Unique identifier for this power redundancy instance.
The following table lists the properties implemented. Property Name Collection Included Property Implementation References HP_PowerRedundancySet Writable Boolean property indicating if the power supply instance referenced by Member will contribute status to the HP_PowerCollection. Property can be modified using the ModifyInstance() intrinsic method.
1-2-7 SMX_HostedPowerCollection Class The SMX_HostedPowerCollection class is used to represent an association between the HP_PowerCollection class and the computer system that contains this collection. The following table lists the properties implemented.
Property Name Property Implementation For example: Power Supply1 at PowerSupplySlot=2 CIM_Location Unique identifier for this power supply location instance. Name Physical position of this Power Supply. PhysicalPosition For example on HP Proliant: Number represents the power supply position printed on the system. HP_Location Location string based on ElementLocationTagDesc.
Property Name Property Implementation CIM_ManagedElement Short description of this power supply for the name displayed by the MP or iLO and its location. Caption For example: Power Supply1 at PowerSupplySlot=2, Power Supply 1a at PowerSupplySlot=2 Description of this power supply module, including ElementName, Type and Status. Description For example: ElementName provides power for PowerSupplyType.
Property Name Property Implementation Short description of this power supply for the name displayed by the MP or iLO and its location. Name For example: Power Supply1 at PowerSupplySlot=2, Power Supply 1a at PowerSupplySlot=2 CIM_PhysicalElement CreationClassName SMX_PowerSupplyModule PartNumber The part number assigned by the organization that is responsible for producing or manufacturing the PhysicalElement. SerialNumber A manufacturer-allocated number used to identify the Physical Element.
The following table lists the properties implemented. Property Name Property Implementation Antecedent References HP_PowerSupplyModule Dependent References HP_PowerSupply 1-2-14 SMX_PowerSupplySlot Class The SMX_PowerSupplySlot class is used to model physical power supply slots on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Short description of this power supply slot.
Property Name Property Implementation CIM_PhysicalPackage ConnectorLayout 6 (Slot) Number Where: represents the number of the power supply slot. 1-2-15 SMX_SystemPowerSupplySlot Class The SMX_SystemPowerSupplySlot class extends the CIM_Container class and association of the HP_ComputerSystemChassis instance with HP_PowerSupplySlot. The following table lists the properties implemented.
Property Name Caption Property Implementation Short description of this power utilization sensor using the name of the power supply displayed by the MP or iLO and its location. For example: Power utilization sensor for Power Supply 1 at PowerSupplySlot=1 Description of this power utilization sensor including the Caption and StatusDescriptions.
Property Name Property Implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_Sensor SensorType 13 (Power Consumption) CurrentState “Normal” PossibleStates Array may contain the following value: PossibleStates[0] = “Normal” CIM_NumericSensor CurrentReading Current reading of the power meter BaseUnits 7 (Watts) RateUnits 0 (None) UnitModifier 0 1-2-18 SMX_SystemPowerMeter SMX_SystemPowerMeter class and associates the HP_ComputerSystem instance with HP_PowerM
1-2-20 SMX_PowerControllerFirmware SMX_PowerControllerFirmware is used to model power controller firmware on Servers. Not all systems support reporting power controller firmware. Property Name Property Implementation CIM_ManagedElement Caption Power controller firmware Description of this power utilization sensor including the Caption and StatusDescriptions. Description For example: Power controller firmware.
Property Name Property Implementation MinorVersion The firmware minor version number, if any RevisionNumber The firmware revision number number, if any 1-2-21 SMX_PowerControllerElementFirmwareIdentity The SMX_PowerControllerElementFirmwareIdentity class associates the HP_ComputerSystem instance with HP_PowerControllerFirmware.
Property Name Property Implementation IndicationIdentifier GUID string generated at the time of indication. IndicationTime Time of indication. CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown. SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses OSType For example: 01.05.
Property Name Property Implementation RackName Rack name if one exists RackUUID Rack Unique Identifier if one exists BladeName HP_ComputerSystem.Name BladeBay HP_BladeCSLocation.LocationInformation[0] 1-3-2 HP_DeviceIndication: Power Supply AC Input Loss Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A power supply has failed – input power lost. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.
1-3-3 HP_DeviceIndication: Power Supply Removed Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A power supply has been removed. PowerSupply Where: PowerSupply is the system power supply that was removed. AlertingManagedElement WBEM Path of the SMX_PowerSupply instance.
Property Name Property Implementation AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the inserted power supply. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 2 ProviderName HP Power RecommendedActions No action is recommended.
Property Name RecommendedActions Property Implementation Check the failed power supply and replace if necessary. HP_AlertIndication Summary Power supply failed EventCategory 16 (System Power) ProbableCause 89 (Power Supply Failure) ProbableCauseDescription Power Supply Failed 1-3-6 HP_DeviceIndication: Power Supply Degraded . Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A power supply has failed.
Property Name Property Implementation ProbableCauseDescription Power supply degraded 1-3-7 HP_DeviceIndication: Power Supply Repaired Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication power supply has been repaired. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has been repaired.
Property Name Property Implementation A fault tolerant power supply is no longer providing power for a power redundancy set. RedundancySetCaption Description Where: RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set with reduced redundancy. AlertingManagedElement WBEM Path of SMX_PowerRedundancySet instance representing the redundancy set with reduced redundancy.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 6 ProviderName HP Power RecommendedActions Check the power supply configuration and check the status of the power redundancy. Ensure the system is being powered adequately. Add or replace power supplies if necessary.
Property Name Property Implementation ProviderName HP Power RecommendedActions Check the power supply configuration and check the status of the power redundancy. Ensure the system is being powered adequately. Add or replace power supplies if necessary.
Property Name Property Implementation Summary Power redundancy restored EventCategory 16 (System Power) ProbableCause 1 (Other) HP Insight Management Power Supply Provider Overview 28
1 HP Insight Management WBEM Profile Registration Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management Profile Registration provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Profile Registration Profile (P00100) HP WBEM TC 1.0.
• SMX_ReferencedProfile • SMX_PRPBaseServerECTP • SMX_FCPBaseServerECTP The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name RegisteredOrganization Property Implementation 1 (Other) for HP extension profiles 2 (DMTF) for DMTF profiles 11 (SNIA) for SNIA SMI-S storage profiles RegisteredVersion The DMTF Profile table lists the property values for this class. The following table lists all possible DMTF Profiles. Some implementations only support a subset of these profiles so only the subset is reported. RegisteredName Registered Version Caption/Description/ElementName Base Server 1.0.
RegisteredName Registered Version Caption/Description/ElementName Extent Composition 1.2.0 SNIA Extent Composition Profile Disk Sparing 1.3.0 SNIA Disk Sparing Profile Generic Initiator Ports 1.3.0 SNIA Generic Initiator Ports Profile DA Target Ports 1.3.0 SNIA DA Target Ports Profile Indication 1.3.0 SNIA Indication Profile Host Hardware RAID Controller 1.1.0 SNIA Host Hardware RAID Controller Profile FC Initiator Port 1.3.0 SNIA FC Initiator Port Profile FC HBA 1.3.
RegisteredName Registered Version Caption/Description/ElementName HP Software Inventory 2.0.0 HP Software Inventory Profile HP Blade System Lite 2.1.0 HP Blade system Lite Profile HP Management Processor Lite 2.1.1 HP Management Processor Lite Profile HP FC HBA 1.0.5 HP FC HBA Profile HP Storage Enclosure 1.0.2 HP Storage Enclosure Profile HP Profile Registration 2.0.0 HP Profile Registration Profile HP Smart Array 2.0.0 HP Smart Array Profile HP SAS HBA 2.0.
Dependent 1-2-4 References CIM_RegisteredProfile (referenced) SMX_PRPBaseServerECTP Class The SMX_PRPBaseServerECTP class extends the CIM_ElementConformsToProfile class and associates the Base Server registered profile with the HP specific central class that defined the implementation of the profile. The following table lists the properties implemented.
SAS HBA Provider Datasheet version 1.05 The following chapters define the supported properties for the SAS HBA provider. For details of each property, see the HP SAS HBA profile (P00122) and associated MOF file. 1-1-1 SMX_SASArraySystem SMX_SASArraySystem represents the top level system. There is one instance per HBA.
SMX_SASArrayController represents the controller. There is one per HBA.
Table 16-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation Name Concatenation of Vendor + Model + SerialNumber+Logical Drive number For example, HP+HP 8 INT Port SAS/SATA HBA+C007760405+LD1 CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASStorageVolume DeviceID Opaque Key SystemCreationClassName SMX_SASArraySystem SystemNa
Table 16-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation OperationalStatus[0] Volume status • 0 (Unknown) • 2 (OK) • 3 (Degraded) - RAID redundancy lost or rebuilding data • 6 (Error) OSName 1-1-4 Corresponding OS name for this volume SMX_SASDiskDrive SMX_SASDiskDrive represents the hard drives connected to SAS HBA controllers.
Table 16-4 Class: SMX_SASDiskDrive (CIM_DiskDrive) Property name Property implementation SMX_SASDiskDrive DriveConfiguration See HP SAS HBA Profile DriveHasMNPData See HP SAS HBA Profile DriveInterface See HP SAS HBA Profile DrivePlacement See HP SAS HBA Profile DriveRotationalSpeed See HP SAS HBA Profile Description • Unknown (If neither SAS or SATA) • SAS (If disk drive interface is SAS) • SATA (If disk drive interface is SATA) NegotiatedDataWidth 0 NegotiatedSpeed 0 This value indicate
Table 16-5 Class: SMX_SASStorageExtent (CIM_StorageExtent) Property name Property implementation OperationalStatus[0] Operational Status for the disk drive • • • • 0 (Unknown) 2 (OK) 5 (Predictive Failure) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASStorageExtent DeviceID Opaque ID SystemCreationClassName SMX_SASArraySystem SystemName SMX_SAS
Table 16-6 Class: SMX_SASDiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation ElementName TargetType value CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement Caption Disk Drive Firmware Description Disk Drive Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string IdentityInfoType [0]CIM:SoftwareFamily [1]HPQ:SoftwareCategory Id
Table 16-7 Class: SMX_SASPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CreationClassName SMX_SASPhysicalPackage Manufacturer Controller vendor string Model Controller model string PartNumber N/A–Not available for this implementation SerialNumber Controller Serial Number Tag HBA Serial number CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) SMX_SASPhysicalPackage 1-1-8 SMX_SASDiskPhysicalPackage SMX_SASDiskPhysicalPackage represents the physical aspects
Table 16-8 Class: SMX_SASDiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation HotSwappable • TRUE—Drive is hot swappable • FALSE—Drive is not hot swappable RemovalConditions • • • • 0 (Unknown) 2 (Not Applicable) 3 (Removable when off) 4 (Removable when on or off) SMX_SASDiskPhysicalPackage 1-1-9 SMX_SASPortController SMX_SASPortController represent the HBA in the host system. There is one instance per HBA.
SMX_SASDAPort represents the front-end port for an HBA in the host system. Direct Attached implies that the array controller is attached to a local bus on the host (for example, PCI).
Table 16-11 Class: SMX_SASFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedSystemElement Name HBA Firmware CIM_LogicalElement Caption HBA Firmware Description HBA Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] HBA Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string IdentityInfoType [0]CIM:SoftwareFamily [1] HPQ:SoftwareCategory IdentityInfoValue [0]HPQ: Set to controller model
Table 16-12 Class: SMX_SASPrimordialPool (CIM_StoragePool) Property name Property implementation RemainingManagedSpace 0 TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all raid drives connected to this controller. SMX_SASPrimordialPool SMX_SASPrimordialPoolNoRaid 1-1-13 SMX_SASPrimordialPoolNoRaid represents the total raw storage managed by the array controller that is not assigned to raid volumes.
Table 16-14 Class: SMX_SASStoragePool (CIM_StoragePool) Property name Property implementation ElementName Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Storage Pool CIM_ManagedSystemElement CIM_LogicalElement CIM_StoragePool InstanceID Opaque key PoolID Controller serial number:1 Primordial FALSE RemainingManagedSpace 0 TotalManagedSpace Total raw space managed by this pool SMX_SASStoragePool 1-1-15 SMX_SASStorageSetting SMX_SASStorageSettin
Table 16-15 Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name Property implementation DeltaReservationMin 0 NoSinglePointOfFailure • FALSE—RAID 0 • TRUE—RAID 1 PackageRedundancyGoal • 0 (RAID 0) • 1 (RAID 1) PackageRedundancyMax • 0 (RAID 0) • 1 (RAID 1) PackageRedundancyMin • 0 (RAID 0) • 1 (RAID 1) SMX_SASStorageSetting SMX_SASSCSIProtocolEndpoint 1-1-16 SMX_SASSCSIProtocolEndpoint represents an access point to storage resources.
Table 16-16 Class: SMX_SASSCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation Role 4 (Both Initiator and Target) SMX_SASSCSIProtocolEndpoint 1-1-17 SMX_SASSCSIProtocolController SMX_SASSCSIProtocolController represents a view a SCSI resources on the controller.
Table 16-18 Class: SMX_SASStorageRedundancySet (CIM_StorageRedundancySet) Property name Property implementation CIM_ManagedElement ElementName Storage Redundancy Set CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key CIM_RedundancySet LoadBalanceAlgorithm 2 (No Load Balancing) MaxNumberSupported 0 MinNumberNeeded 0 RedundancyStatus • 2 (Fully Redundant) • 4 (Redundancy Lost) TypeOfSet[0] 5 (Limited Sparing) CIM_StorageRedundancySet SMX_SASStorageRedundancySet 1-1-19 SMX_SASS
SMX_SASArraySystemLocation 1-1-20 SMX_SASArraySystemLocation represents a location string for the HBA.
Table 16-21 Class: SMX_SASDiskDriveLocation (HP_Location) Property name Property implementation CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number or SCSI ID of Disk ElementLocationTagDesc 20 (Bay) or 21 (SCSI ID) SMX_SASDiskDriveLocation 1-1-22 SMX_SASStorageCapabilities SMX_SASStorageCapabilities represents the possible capabilities of a Storage Pool.
Table 16-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation ElementType 5 (Storage Pool) NoSinglePointOfFailure • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) • False—When number of drives = 1 or Pool is NonRAID • True—When number of drives > 1 (For example, NoSinglePointOfFailureDefault Pool can be configured for redundancy.
SMX_SASDriveCage represents the drive cage assembly and back plane within a storage enclosure. There can be multiple instances within a duplexed enclosure.
Table 16-25 Class: SMX_SASEnclosureFirmware (CIM_SoftwareIdentity) Property name Property Implemenation Name Storage Enclosure Firmware CIM_LogicalElement Caption Storage Enclosure Firmware Description Storage Enclosure Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string IdentityInfoType [0]CIM:SoftwareFamily [1] HPQ:SoftwareCategory IdentityInfoValue [0]HPQ:
Table 16-26 Class: SMX_SASStorageEnclosure (HP_StorageEnclosure) Property name Property implementation PartNumber N/A—Not available in this implementation SerialNumber Enclosure Serial Number N/A is reported if there is no serial number (for example, internal enclosures).
Table 16-27 Class: SMX_SASStorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SASStorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated[0] 2 (Other) IdentifyingDescriptions[0] Other Vendor Specific Name OtherDedicatedDescriptions[0] SDE - indicates Stora
SMX_SASSmartDriveCarrierAppFirmware Class 1-1-29 The SMX_SASSmartDriveCarrierAppFirmware class implements the CIM_SoftwareIdentity class and represents the firmware installed on a Smart Drive Carrier. This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the properties implemented.
SMX_SASSmartDriveCarrierBootldrFirmware Class 1-1-30 The SMX_SASSmartDriveCarrierBootldrFirmware class implements the CIM_SoftwareIdentity class and represents the firmware installed on a Smart Drive Carrier Bootloader. This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the properties implemented.
SMX_SASDriveCageDiskPhysicalPackage (Association) 1-1-31 Table 16-29 Class: SMX_SASDriveCageDiskPhysicalPackage (CIM_Container) 1-1-32 Property name Property implementation GroupComponent SMX_SASDriveCage PartComponent SMX_SASDiskPhysicalPackage SMX_SASStorageEnclosureDriveCage (Association) Table 16-30 Class: SMX_SASStorageEnclosureDriveCage (CIM_Container) Property name Property implementation GroupComponent SMX_SASStorageEnclosure PartComponent SMX_SASDriveCage SMX_SASStorageEnclosureEnc
SMX_SASStorageEnclosureProcessorEnclosureFirmwar e (Association) 1-1-35 Table 16-33 Class: SMX_SASStorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASEnclosureFirmware Dependent SMX_SASStorageEnclosureProcessor ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) SMX_SASStorageEnclosureStorageEnclosureProcessor (Association) 1-1-36 Table 16-34 Class: SMX_SASStorageEncl
Table 16-36 Class: SMX_SASPrimordialPoolStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation ManagedElement SMX_SASPrimordialPool SMX_SASPrimordialPoolNoRaidStorageCapabilities (Association) 1-1-39 Table 16-37 Class: SMX_SASPrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElement SMX_SASPrimordialPoolNoRaid SMX_SASStoragePoolStorageCapabilities (Association) 1-1
Table 16-40 Class: SMX_SASArraySystemPortController (CIM_Logicaldentity) 1-1-43 Property name Property implementation SameElement SMX_SASArraySystem SystemElement SMX_SASPortController SMX_SASArraySystemDiskDrive (Association) Table 16-41 Class: SMX_SASArraySystemDiskDrive (CIM_SystemDevice) 1-1-44 Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASDiskDrive SMX_SASArraySystemStorageVolume (Association) Table 16-42 Class: SMX_SASArraySystemStorageVol
1-1-47 SMX_SASArraySystemPrimordialPool (Association) Table 16-45 Class: SMX_SASArraySystemPrimordialPool (CIM_HostedStoragePool) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASPrimordialPool SMX_SASArraySystemPrimordialPoolNoRaid (Association) 1-1-48 Table 16-46 Class: SMX_SASArraySystemPrimordialPoolNoRaid (CIM_HostedStoragePool) 1-1-49 Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASPrimordialPoolN
Table 16-49 Class: SMX_SASArraySystemArrayController (CIM_ComponentCS) 1-1-52 Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASArrayController SMX_SASProductPhysicalPackage (Association) Table 16-50 Class: SMX_SASProductPhysicalPackage (CIM_ProductPhysicalPackage) 1-1-53 Property name Property implementation GroupComponent SMX_SASProduct PartComponent SMX_SASPhysicalPackage SMX_SASStoragePoolStorageExtent (Association) Table 16-51 Class: SMX_SASSto
Table 16-53 Class: SMX_SASPrimordialPoolNoRaidStorageExtent (CIM_ConcreteComponent) Property name Property implementation PartComponent SMX_SASStorageExtent SMX_SASStorageSpecificCollectionArraySystem (Association) 1-1-56 Table 16-54 Class: SMX_SASStorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection SMX_SASStorageSpecificCollection Member SMX_SASArraySystem SMX_SASStorageRedundancySetStorageExtent (Association) 1-1-57 Table 16-55 Clas
Table 16-57 Class: SMX_SASSCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation Antecedent SMX_SASSCSIProtocolController Dependent SMX_SASStorageVolume DeviceNumber Device LUN number DeviceAccess 2 (Read Write) SMX_SASFirmwareArraySystem (Association) 1-1-60 Table 16-58 Class: SMX_SASFirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASFirmware Dependent SMX_SASArraySystem ElementSoft
SMX_ SASSmartDrvCarrierAppInstalledFirmwareIdentity (Association) 1-1-63 This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the associations implemented for this class.
Table 16-60 Class: SMX_SASDiskPhysicalPackageDiskDrive (CIM_Realizes) 1-1-67 Property name Property implementation Antecedent SMX_SASDiskPhysicalPackage Dependent SMX_SASDiskDrive SMX_SASStoragePoolStorageVolume (Association) Table 16-61 Class: SMX_SASStoragePoolStorageVolume (CIM_AllocatedFromStoragePool) 1-1-68 Property name Property implementation Antecedent SMX_SASStoragePool Dependent SMX_SASStorageVolume SpaceConsumed Bytes consumed by volume SMX_SASPrimordialPoolStoragePool (Associa
Table 16-64 Class: SMX_SASStorageExtentStorageVolume (CIM_BasedOn) 1-1-71 Property name Property implementation Antecedent SMX_SASStorageExtent Dependent SMX_SASStorageVolume SMX_SASDAPortSCSIProtocolEndpoint (Association) Table 16-65 Class: SMX_SASDAPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent SMX_SASDAPort Dependent SMX_SASSCSIProtocolEndpoint SMX_SASStorageGroupHostedCollection (Association) 1-1-72 Table 16-66 Class: SMX_SASStora
Table 16-68 Class: SMX_SASPhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASPhysicalPackage Physical Location SMX_SASArraySystemLocation SMX_SASDiskPhysicalPackageDiskDriveLocation (Association) 1-1-75 Table 16-69 Class: SMX_SASDiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASDiskPhysicalPackage PhysicalLocation SMX_SASDiskDriveLocation SMX_SASSCSIProtoco
Table 16-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation Description A SAS/SATA HBA status has changed from non-OK to OK. AlertingManagedElement WBEM Path of controller AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table 16-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table 16-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation Description A SAS/SATA HBA status has changed to Error. AlertingManagedElement WBEM Path of controller AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 2 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Replace the HBA.
Table 16-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table 16-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation Description A physical drive status has changed from non-OK to OK. AlertingManagedElement WBEM Path of disk drive AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 201 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table 16-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation VariableTypes • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16) VariableValues • VariableValues[0]: Short Description of failure • VariableValues[1]: HPSA_DiskDrive.DriveInterface In some cases, the property VariableValues can have N/A or “” values.
Table 16-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity Severity For example, 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Error.
Table 16-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
1-2-5 Physical Drive status REBUILDING Table 16-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity Severity For example, 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Rebuilding. Data is now being rebuilt onto this drive from the RAID set.
Table 16-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication Var
Table 16-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation HP_DeviceIndication DeviceModel 1-2-6 Disk Model string Physical Drive status PREDICTIVE FAILURE Table 16-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical dri
Table 16-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation OSType • • On ESXi, 39 (VM) • On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table 16-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk Location string For example, Bay 3 HWManufacturer Disk Manufacturer string Disk Serial Number HWSerialNumber HP_DeviceIndication DeviceModel Disk Model string Physical Drive status PREDICTIVE FAILURE due to Solid State Drive Wear out 1-2-7 Table 16-77 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out P
Table 16-77 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out Property name Property implementation Summary Physical drive in predictive failure state due to SSD wear out EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Predictive Failure due to Solid state wear out ProviderVersion Provider version generating the indication in the format, ...
Table 16-77 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Na
Table 16-78 HP_DeviceIndication: Logical Drive status OK Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table 16-78 HP_DeviceIndication: Logical Drive status OK 1-2-9 Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing
Table 16-79 HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation ProbableCause 86 (Disk Failure) ProbableCauseDescription Logical Drive Status Changed to Error ProviderVersion Provider version generating the indication in the format, ...
Table 16-79 HP_DeviceIndication: Logical Drive status ERROR 1-2-10 Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Table 16-80 HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
Enclosure Power Supply status changed to Non Redundant 1-2-11 Table 16-81 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem status has changed to non-redundant.
Table 16-81 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table 16-81 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation HP_DeviceIndication DeviceModel Enclosure Model string Enclosure Power Supply Status changed to OK (Redundant) 1-2-12 Table 16-82 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime T
Table 16-82 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation OSType • • On ESXi, 39(VM) • On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table 16-82 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Enclosure Power Supply Status changed to Redundant Degraded 1-2-13 Table 16-83 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation CIM_Indica
Table 16-83 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation ProbableCauseDescription Redundant Power Supply Degraded ProviderVersion Provider version generating the indication in the format, ...
Table 16-83 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Table 16-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType • • On ESXi, 39(VM) • On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the ind
Table 16-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product envir
Table 16-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
Table 16-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table 16-86 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation Description A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs.
Table 16-86 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
Table 16-87 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status has changed from a non-OK state to OK.
Table 16-87 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values
Table 16-88 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there might be a problem with one or more of the fans.
Table 16-88 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indicat
1-2-19 Enclosure Fan Status change to Failure Table 16-89 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan Status changed to Failure.
Table 16-89 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the format: ..
Table 16-89 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation HP_DeviceIndication DeviceModel Enclosure Model string
1 HP Insight Manager WBEM Smart Component Installer Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Smart Component Installer implements and extends CIM classes described in this document to support installation of HP SmartComponents. This provider supports the InstallFromURI() method with the http URI scheme to retrieve and install HP Smart Components. Profile Name Organization Version DMTF Software Update Profile (DSP 1025) DMTF 1.0.
• SMX_SCInstallationService • SMX_SCInstallationServiceCapabilities • SMX_SCInstallerHostedService • SMX_SCInstallerElementCapabilities • SMX_SCInstallerConcreteJob • SMX_SCInstallerJobHostedDependency • SMX_SCInstallerOwningJobElement The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_Service CreationClassName SMX_SCInstallationService SystemCreationClassName SMX _ComputerSystem SystemName SMX_ComputerSystem.
1-2-1-1 Implemented Methods for SMX_SCInstallationService Class Method Name Method Implementation Must be root to request this method. Unless specified, the matching value in the InstallOptionValues[]for each InstallOptions[] is NULL or an empty string. Must set either install or discovery option.
1-2-2 SMX_SCInstallationServiceCapabilities Class The SMX_SCInstallationServiceCapabilities class implements the HP_SoftwareInstallationServiceCapabilities class to model the installation service capabilities. There is only one instance of SMX_SCInstallationServiceCapabilities instantiated on a server. The following table lists the properties implemented.
Property Name Property Implementation in as . This is used by components that do self-discovery to let higher level applications such as HP Smart Update Manager (HP SUM) whether a particular device needs to be updated when in a multi-target environment. 32770: Smart Component –d (Discovery) 32771: Smart Component –g or Downgrade. This value instructs the firmware to be installed if the version of firmware to be deployed is earlier than or newer than what is already installed.
Property Name Property Implementation CIM_HostedDependency CIM_HostedService Capability References SMX_SCInstallationServiceCapability ManagedElement References SMX_SCInstallationService Characteristics[] 2: Default 3: Current SMX_SCInstallerElementCapability 1-2-5 SMX_SCInstallerConcreteJob Class The SMX_SCInstallerConcreteJob class implements the HP_InstallerConcreteJob class to model an execution of the Smart Component installation service.
Property Name Property Implementation OperationalStatus 2 (OK) StatusDescriptions StatusDescriptions[0] will contain OK CIM_Job PercentComplete 0-100 – proper calculation of percent complete requires client to use the SmartComponent estimated execution time install option. DeleteOnCompletion True StartTime The time the job started. 0-7 - return code from Smart Component 0-7 ErrorCode 7- internal error in provider, SmartComponent not executed 500 - download of SmartComponent failed.
Property Name Property Implementation SMX_SCInstallerConcreteJob 1-2-5-1 Implemented Methods for SMX_SCInstallerConcreteJob Class Method Name Method Implementation Get the detailed status of the last execution of the Smart Component.
4097 : Invalid State Transition. state. Job is not in running 4098 : Use of Timeout Parameter Not Supported. 1-2-6 SMX_SCInstallerOwningJobElement Class The SMX_SCInstallerOwningJobElement class implements the CIM_OwningJobElement class and associates instances of SMX_SCInstallerConcreteJob and SMX_SCInstallationService. The following table lists the properties implemented.
1 HP Insight Management WBEM System Temperature Sensor Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management System Temperature Sensor provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Sensor Profile HP WBEM TC 1.
Schema Supported by the Provider This provider supports the following classes: • SMX_NumericSensor • SMX_SensorCollection • SMX_SystemSensor • SMX_HostedSensorCollection • SMX_MemberOfSensorCollection The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation CIM_ManagedSystemElement 2 (OK) – if temperature reported by the sensor is within normal operating range; OperationalStatus[0] 2 (OK) – if temperature reported by the sensor has exceeded its non-critical threshold and has set fans to full speed; 6 (Error) – if temperature reported by the sensor has exceeded its threshold and the system is gracefully shutting down.
Property Name CurrentState Property Implementation Normal – if OperationalStatus[0] is 2 (OK); Critical – if OperationalStatus[0] is 6 (Error); Array can contain any of the following values: PossibleStates PossibleStates[0] = Normal; PossibleStates[1] = Critical; CIM_NumericSensor CurrentReading Current reading of temperature sensor BaseUnits 2 (Degrees C) RateUnits 0 (None) UnitModifier 0 SupportedThresholds[0] = 1 (UpperThresholdNotCritical) if the system will set fans to full speed if the thr
1-2-2 SMX_SensorCollection Class The SMX_SensorCollection class implements the HP_SensorCollection and is used to model temperature sensor collections on servers. There is one instance of this class on systems modeling sensors. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Temperature Sensor Collection This is a collection of temperature sensors. GroupStatusDescription.
1-2-3 SMX_MemberOfSensorCollection Class The SMX_MemberOfSensorCollection class implements the HP_MemberOfSensorCollection class and is used to represent an association between the SMX_NumericSensor and SMX_SensorCollection classes. The following table lists the properties implemented.
HP_AlertIndication: Temperature Sensor Threshold Exceeded 1-3-1 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication. PerceivedSeverity 5 (Major) IndicationTime Time of indication. CIM_AlertIndication Description A temperature sensor has detected that the temperature has exceeded the normal operating range. Where: is the SMX_NumericSensor.Caption for the sensor that has failed.
Property Name Property Implementation ProviderVersion For example: 2.2.0.0 NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication. OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: major.minor.build SystemFirmwareVersion Firmware version of the computer system generating the indication.
Property Name Property Implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name, if one exists. RackUID * Rack Unique Identifie, if one exists. SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment. SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment.
Property Name Property Implementation RecommendedActions No action is recommended. SystemName HP_ComputerSystem.Name SystemCreationClassName HP_ComputerSystem.CreationClassName HP_AlertIndication Summary Threshold exceeded condition recovery EventCategory 23 (System Cooling) ProbableCause 52 (Threshold Crossed) ProbableCauseDescription Threshold Exceeded Condition has Recovered ProviderVersion For example: 2.2.0.
Property Name Property Implementation RackName * Rack name, if one exists. RackUID * Rack Unique Identifier, if one exists. SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment. SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment.
1 HP Insight Management WBEM Smart Array Provider The HP Insight Management Web-Based Enterprise Management (WBEM) Management Smart Array provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider only supports internal storage and direct attached external storage, such as MSA 60/70.
HP Insight Management WBEM Smart Array Provider 2
Schema Supported by the Provider This provider supports the following classes: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • SMX_SAArraySystem SMX_SAArrayController SMX_SAStorageVolume SMX_SADiskDrive SMX_SAStorageExtent SMX_SADiskDriveFirmware SMX_SAPhysicalPackage SMX_SAArrayControllerPhysicalPackage SMX_SADiskPhysicalPackage SMX_SAStorageEnclosure SMX_SAStorageEnclosureProcessor SMX_SAPortController SMX_SADAPort SMX_SAFirmware SMX_SAEnclosureFirmware SMX_
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • SMX_SAArraySystemDAPort (Association) SMX_SMX_SAArraySystemDAPort (CIM_SystemDevice) SMX_SAArraySystemPrimordialPool (Association) SMX_SAArraySystemStoragePool (Association) SMX_SAComputerSystemArraySystem (Association) SMX_SAArraySystemArrayController (Association) SMX_SAStorageEnclosureStorageEnclosureProcessor (Association) SMX_SAProductPhysicalPackage (Association) SMX_SAStorageEnclosureDriveCage (Asso
• SMX_SAPortControllerPCIDevice The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation More info for OperationalStatus result. This provides a short Description to identify who is contributing to non-OK status.
Property Name Property Implementation Dedicated[0]: Dedicated 3 (Storage) Dedicated[1]: 15 (Block Server) IdentifyingDescriptions Other Vendor Specific Name Controller Serial Number EMBEDDED- will be reported if there is no Serial Number for device is local OtherIdentifyingInfo For example: embedded on motherboard. PCISLOT- will be reported if there is no Serial Number for device is local. For example: a PCI occupies slot.
Property Name Property Implementation Status for Array Controller. OperationalStatus[0] 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SAArrayController Controller Serial Number. EMBEDDED- will be reported if there is no Serial Number. Name For example: embedded on motherboard.
Property Name Property Implementation CacheParityWriteErrors See HP Smart Array Profile CacheReadPercent See HP Smart Array Profile CacheSerialNumber See HP Smart Array Profile CacheSizeTotal See HP Smart Array Profile CacheState See HP Smart Array Profile CacheStatus See HP Smart Array Profile CacheWritePercent See HP Smart Array Profile ControllerStatus See HP Smart Array Profile ExpandPriority See HP Smart Array Profile NumberOfPorts See HP Smart Array Profile RebuildPriority See H
Property Name Property Implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SAStorageVolume DeviceID Opaque Key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name NameFormat Property Implementation 2 (VPD83NAA6) HPSA_Storagevolume Accelerator See HP Smart Array Profile Deleteable See HP Smart Array Profile FaultTolerance See HP Smart Array Profile OperationalStatus[0, 1] Volume status. DMTF defined value will be populated in index[0] and extended status will be populated in index[1] per HP Smart Array Profile. OSName Corresponding OS name for this volume.
Property Name Property Implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SADiskDrive DeviceID Opaque value SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
1-2-5 SMX_SAStorageExtent Class The SMX_SAStorageExtent class implements the HPSA_StorageExtent class and represents the consumable storage that is available on a disk drive. There is one instance per disk drive. The following table lists the properties implemented.
Property Name Property Implementation BlockSize Block size in bytes ConsumableBlocks Total number of blocks on disk drive This will indicate extended status for the disk drive ExtentStatus[0] Possible values: 2 (None) 11 (Rebuild – disk drive is currently rebuilding data) NumberOfBlocks Total number of blocks on disk drive Primordial Set to True TotalPowerOnHours Total service hours reported disk drive HPSA_StorageExtent 1-2-6 SMX_SADiskDriveFirmware Class The SMX_SADiskDriveFirmware class i
Property Name Manufacturer Property Implementation Disk drive vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]Storage Device VersionString Drive firmware as reported from SCSI identify command HPSA_DiskDriveFirmware 1-2-7 SMX_SAPhysicalPackage Class The SMX_SAPhysicalPackage class implements the HPSA_PhysicalPackage class and represents the overall physical package for the array system as a whole.
N/A – Not Available for this implementation Version CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSA_PhysicalPackage 1-2-8 SMX_SAArrayControllerPhysicalPackage Class The SMX_SAArrayControllerPhysicalPackage class implements the HPSA_ArrayControllerPhysicalPackage class and represents the physical aspects of any Smart Array controller. There is one instance per HBA. The following table lists the properties implemented.
CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSA_ ArrayControllerPhysicalPackage 1-2-9 SMX_SADiskPhysicalPackage Class The SMX_SADiskPhysicalPackage class represents the physical aspects of the disk drive. There is one instance per disk drive. The following table lists the properties implemented.
Property Name Property Implementation 2 (Not Applicable) RemovalConditions 3 (Removable when off) 4 (Removable when on or off) HPSA_ DiskPhysicalPackage 1-2-10 SMX_SAStorageEnclosure Class The SMX_SAStorageEnclosure class implements the HPSA_StorageEnclosureclass and represents the physical chassis for an internal or externally attached enclosure.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Port: Box: ElementName Where: is the port and is the box number. CIM_ManagedSystemElement Port: Box: Name Where: is the port and is the box number.
Property Name Property Implementation See HP Storage Enclosure Profile Location HPSA_StorageEnclosure 1-2-11 SMX_SAStorageEnclosureProcessor Class The SMX_SAStorageEnclosureProcessor class represents the management processor within a Storage Enclosure. This instance contains the operational status for all managed components in the enclosure if applicable. The following table lists the properties implemented.
Property Name Property Implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SAStorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated[0] 2 (Other) IdentifyingDescriptions[0] Other Vendor Specific Name OtherDedicatedDescriptions[0] SDE - indicates Storage Device Enclosure Port Number:BoxNumber enclosure is attached to.
Property Name Property Implementation CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SAPortController DeviceID Controller serial number SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name Property Implementation Controller name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement ElementName Smart Drive Carrier Application Firmware CIM_ManagedSystemElement Name Smart Drive Carrier Application Firmware CIM_LogicalElement Caption Smart Drive Carrier Application Firmware Description Smart Drive Carrier Application Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Smart Drive Carrier Application Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string [0]CIM:Sof
Property Name Property Implementation CIM_ManagedSystemElement Name Smart Drive Carrier Bootloader Firmware CIM_LogicalElement Caption Smart Drive Carrier Bootloader Firmware Description Smart Drive Carrier Bootloader Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Smart Drive Carrier Bootloader Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ:
Property Name Property Implementation CIM_LogicalElement Caption Storage Enclosure Processor Firmware Description Storage Enclosure Processor Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Processor Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]StorageDevice VersionString Enclosure firmware string Ta
Property Name Property Implementation CIM_ManagedSystemElement CIM_LogicalElement CIM_StoragePool InstanceID Opaque key PoolID Controller serial number Primordial Always set to TRUE RemainingManagedSpace Remaining raw space on controller. This is calculated by summing the remaining space on all drives attached to the controller. TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all drives connected to this controller.
Property Name Property Implementation PoolID Controller serial number: where n is the array number as supplied from API. Primordial Always set to FALSE RemainingManagedSpace Remaining raw space in current pool TotalManagedSpace Total raw space managed by this pool HPSA_StoragePool 1-2-20 SMX_SAMediaAccessStatData Class The SMX_SAMediaAccessStatData class implements the HPSA_MediaAccessStatData and represents the Monitoring and Performance data counters on HP Disk Drives.
Property Name Property Implementation FormatErrors See HP Smart Array Profile HardReadErrors See HP Smart Array Profile HardwareErrors See HP Smart Array Profile HardWriteErrors See HP Smart Array Profile HotPlugCount See HP Smart Array Profile MediaFailures See HP Smart Array Profile NotReadyErrors See HP Smart Array Profile OtherTimeOuts See HP Smart Array Profile SCSIBusFaults See HP Smart Array Profile SectorsRead See HP Smart Array Profile SectorsWritten See HP Smart Array Profil
Property Name Property Implementation RAID Where: is the RAID Description.
Property Name Property Implementation 0 (RAID 0) PackageRedundancyMin 1 (RAID 1, RAID 1+0, RAID 4, RAID 5, RAID 5+1) 2 (RAID 6, RAID 50, RAID 60) HPSA_StorageSetting 1-2-22 SMX_SADriveCage Class The SMX_SADriveCage class implements the HPSA_DriveCage class and represents the drive cage assembly and back plane within a storage enclosure. There may be multiple instances within a duplexed enclosure.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Port ElementName Where: is the name of the port this drive cage is connected.
1-2-23 SMX_SASCSIProtocolEndpoint Class The SMX_SASCSIProtocolEndpoint class implements the HPSA_SCSIProtocolEndpoint class and represents an access point to storage resources. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and . Refer to “Physical Location” for more information.
Property Name Property Implementation 0 (Unknown) 2 (Initiator) Role 3 (Target) 4 (Both Initiator and Target) HPSA_SCSIProtocolEndpoint 1-2-24 SMX_SASCSIProtocolController Class The SMX_SASCSIProtocolController class implements the HPSA_SCSIProtocolController class and represents a view a SCSI resources on the array controller. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and .
Property Name RequestedState Property Implementation 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASCSIProtocolController DeviceID Opaque key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name Property Implementation 2 (Fully Redundant) RedundancyStatus 4 (Redundancy Lost) 5 (Limited Sparing) TypeOfSet[0] CIM_StorageRedundancySet HPSA_StorageRedundancySet 1-2-26 SMX_SAStorageSpecificCollection Class The SMX_SAStorageSpecificCollection class implements the HPSA_StorageSpecificCollection class and represents a collection of smart array controllers that have been grouped together to report consolidated status. The following table lists the properties implemented.
1-2-27 SMX_SADriveCageLocation Class The SMX_SADriveCageLocation class implements the HPSA_DriveCageLocation class and represents a location string for the drive cage. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement Smart Array in Caption Refer to “Physical Location” for more information. Description Same as Caption. ElementName Same as Caption.
Property Name Property Implementation Controller name, Drive Type and Disk Location For example: Smart Array E500 Physical Drive – Port: 1E Box 1 Bay: 5 Caption Controller name, Drive Type and Disk Location Description For example: Smart Array E500 Physical Drive - Port: 1E Box 1 Bay: 5 Controller name, Drive Type and Disk Location ElementName For example: Smart Array E500 Physical Drive - Port: 1E Box 1 Bay: 5 CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTa
Property Name ElementName Property Implementation Same as Caption. CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location For Internal HBA’s: PCI Slot Number ElementLocationTag For example: 3 – for adapter in PCI Slot 3 For example: 0 – for Embedded adapter ElementLocationTagDesc 23 (Adapter) – for Internal HBA’s Array of text values representing the location components that describe this Ethernet Controller Physical location.
Property Name Property Implementation For Primodial Pools: Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal ElementName For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name Property Implementation 0 (When number of drives <= 1) PackageRedundancyDefault 1 (When number of drives = 2 or 3) 2 (When number of drives > 3) 0 (When number of drives <= 1) PackageRedundancyMax 1 (When number of drives = 2 or 3) 2 (When number of drives > 3) PackageRedundancyMin 0 HPSA_StorageCapabilities 1-2-32 SMX_SAProduct Class The SMX_SAProduct class implements the HPSA_Product class and represents the top level marketing information for the array system.
1-2-33 SMX_SAStorageEnclosureLocation Class The SMX_SAStorageEnclosureLocation class implements the HPSA_StorageEnclosureLocation class and represents a location string for the enclosure. The following table lists the properties implemented. Property Name Property Implementation Enclosure location ElementName Port: Box: Where: is the port and is the box number. Enclosure location Port: Box: Caption Where: is the port and is the box number.
Property Name IsDefault 1-2-35 Property Implementation 1 (Set to Is Default) SMX_SAPrimordialPoolStorageCapabilities (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Capabilities SMX_SAStorageCapabilities ManagedElement SMX_SAPrimordialPool 1-2-36 SMX_SAStoragePoolStorageCapabilities (Association) The following table lists the associations implemented for this class.
PartComponent 1-2-39 SMX_SASCSIProtocolController SMX_SAArraySystemPortController (Association) The following table lists the associations implemented for this class. Property Name Property Implementation SameElement SMX_SAArraySystem SystemElement SMX_SAPortController 1-2-40 SMX_SAArraySystemDiskDrive (Association) The following table lists the associations implemented for this class.
1-2-43 SMX_SAArraySystemDAPort (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SADAPort 1-2-44 SMX_SAArraySystemPrimordialPool (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAArrayController SMX_SAStorageEnclosureStorageEnclosureProcessor (Association) 1-2-48 The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAStorageEnclosure Dependent SMX_SAStorageEnclosureProcessor 1-2-49 SMX_SAProductPhysicalPackage (Association) The following table lists the associations implemented for this class.
GroupComponent SMX_SAPhysicalPackage PartComponent SMX_SAArrayControllerPhysicalPackage 1-2-52 SMX_SAPhysicalPackageStorageEnclosure (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAPhysicalPackage PartComponent SMX_SAStorageEnclosure 1-2-53 SMX_SADriveCageDiskPhysicalPackage (Association) The following table lists the associations implemented for this class.
SMX_SAStorageRedundancySetStorageExtent (Association) 1-2-56 The following table lists the associations implemented for this class. Property Name Property Implementation Collection SMX_SAStorageRedundancySet Member SMX_SAStorageExtent 1-2-57 SMX_SAArraySystemFirmware (Association) The following table lists the associations implemented for this class.
Dependent SMX_SAArraySystem ElementSoftwareStatus[0]: ElementSoftwareStatus 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_SAStorageEnclosureProcessorEnclosureFirmware (Association) 1-2-60 The following table lists the associations implemented for this class.
SMX_SASmartDrvCarrierAppElementFirmwareIdentity (Association) 1-2-62 This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent HPSA_SmartDriveCarrierAppFirmware Dependent HPSA_SADiskDrive SMX_ SASmartDrvCarrierAppInstalledFirmwareIdentity (Association) 1-2-63 This class is implemented only when the hardware includes Smart Drive Carrier support.
SMX_ SASmartDrvCarrierBootldrInstalledFirmwareIdentity (Association) 1-2-65 This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the associations implemented for this class. Property Name Property Implementation System HPSA_ArraySystem InstalledSoftware HPSA_SmartDriveCarrierBootldrFirmware 1-2-66 SMX_SADiskDriveStorageExtent (Association) The following table lists the associations implemented for this class.
Dependent SMX_SAStorageVolume SpaceConsumed Bytes consumed by volume 1-2-69 SMX_SAPrimordialPoolStoragePool (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAPrimordialPool Dependent SMX_SAStoragePool SpaceConsumed Bytes consumed by storage pool 1-2-70 SMX_SASpareExtentStorageExtent (Association) The following table lists the associations implemented for this class.
Dependent 1-2-73 SMX_SAStorageVolume SMX_SADAPortSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SADAPort Dependent SMX_SASCSIProtocolEndpoint 1-2-74 SMX_SAStorageGroupHostedCollection (Association) The following table lists the associations implemented for this class.
1-2-77 SMX_SADiskDriveMediaAccessStatData (Association) The following table lists the associations implemented for this class. Property Name Property Implementation ManagedElement SMX_SADiskDrive Stats SMX_SAMediaAccessStatData SMX_SAArrayControllerPhysicalPackageArrayControllerL ocation (Association) 1-2-78 The following table lists the associations implemented for this class.
SMX_SADiskPhysicalPackageDiskDriveLocation (Association) 1-2-81 The following table lists the associations implemented for this class. Property Name Property Implementation Element SMX_SADiskPhysicalPackage PhysicalLocation SMX_SADiskDriveLocation SMX_SASCSIProtocolEndpointSCSIProtocolController (Association) 1-2-82 The following table lists the associations implemented for this class.
Property Name Property Implementation instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE Protocol Endpoint for Caption Where is the value populated in the ElementName property of the instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE CIM_ManagedSystemElement SMX_SADiskDrive.DeviceID: Name Where
1-2-85 SMX_SAISASSCSIProtocolEndpoint SMX_SAISASSCSIProtocolEndpoint implements HPSA_SAISASSCSIProtocolEndpoint and HPSA_SAISASSCSIProtocolEndpoint represents each port on the smart array controller. The following table lists the associations implemented for this class.
Property Name Property Implementation CIM_ManagedElement Protocol Endpoint for Where: is the value populated in the ElementName property of the instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE Caption Protocol Endpoint for ElementName Where: is the value populated in the ElementName property of the instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE CIM_ManagedSystemElement The same
Property Name Property Implementation Port ElementName Where: is a unique index across all ports on a single drive CIM_ManagedSystemElement 2 (OK) OperationalStatus For multi-path supported firmware implementations, the status of the port is OK, and the status of the path is the only element that can be detected.
Property Name Property Implementation CIM_ManagedElement Port Caption Where: is the port number For example: 1E, 2E, and so on Port ElementName Where: is the port number For example: 1E, 2E, and so on CIM_ManagedSystemElement 2 (OK) OperationalStatus For multi-path supported firmware implementations, the status of the port is OK, and the status of the path is the only thing that can be detected.
Property Name PortType Property Implementation 94 (SAS) CIM_SASPort PermanentAddress 1-2-88 Not supported SMX_SAISASPortISASSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAISASPort Dependent SMX_SAISASSCSIProtocolEndpoint SMX_SAArraySystemISASSCSIProtocolEndPoint (Association) 1-2-89 The following table lists the associations implemented for this class.
Property Name Property Implementation Antecedent SMX_SAPortController Dependent SMX_SAISASPort SMX_SAArraySystemTSASSCSIProtocolEndpoint (Association) 1-2-92 The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAArraySystem Dependent SMX_SATSASSCSIProtocolEndpoint 1-2-93 SMX_SATSASPortTSASSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class.
AvailableSAP SMX_SATSASSCSIProtocolEndpoint ManagedElement SMX_SADiskDrive 1-2-96 SMX_SASCSIInitiatorTargetLogicalUnitPath The following table lists the associations implemented for this class.
Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed from a nonOK state to OK.
Property Name Property Implementation ProviderVersion For example: 2.2.0.
Property Name Property Implementation HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number HP_DeviceIndication DeviceModel Physical Disk Model string Controller Location DeviceControllerLogicalLocation For example: SmartArray 642 in Slot 2 FailureDescription VariableNames[] DriveInterface LastFailureDescription VariableTypes[] String (1) uint16 (4) FailureDescription – short description of the failure VariableValues[] Drive interface H
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 202 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions Check for failed or removed physical drives.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation FailureDescription – short description of the failure VariableValues[] Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name SystemCreationClassName Property Implementation CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive is now rebuilding. EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Physical Drive Status Changed to Rebuilding NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
Property Name Property Implementation EnclosureName * HP_BladeEnclosureCS.
HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE 1-3-4 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Predictive Failure.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number FailureDescription VariableNames[] DriveInterface LastFailureDescription VariableTypes[] String (1) uint16 (4) FailureDescription – short description of the failure VariableValues[] Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name Property Implementation out. AlertingManagedElement WBEM Path of SMX_SADiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 206 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions Replace drive immediately to avoid loss of data.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
Property Name VariableTypes[] Property Implementation String (1) uint16 (4) FailureDescription – short description of the failure VariableValues[] Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name Property Implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation Previous OperationalStatus values for Storage Volume DeviceOperationalStatusPrevious[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatusPrevious DeviceOperationalStatusPrevious[1]: SMX_SAStorageVolume.
Property Name Property Implementation Summary Logical drive status error EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Logical Drive Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v.. HP_HardwareIndication Logical drive number & RAID Level. HWLogicalLocation For example: LogicalDrive1 (RAID 1+0).
Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A logical drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation VariableNames[] FailureDescription VariableTypes[] String (1) VariableValues[] FailureDescription short description of the failure HP_DeviceIndication SMX_SAStorageVolumeIndication Current OperationStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatus DeviceOperationalStatus[1]: SMX_SAStorageVolume.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation EventCategory 6 (Primary Storage) ProbableCause 24 (I/O device error) ProbableCauseDescription Array Controller Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name SolutionProductModel Property Implementation Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Property Name Property Implementation Description A Smart Array controller Battery status has changed from non-OK to OK. AlertingManagedElement WBEM Path to SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 6 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name SolutionProductModel Property Implementation Conditional property containing the Solution Name string when running in a aggregate product environment in the format v.. 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.
Property Name Property Implementation FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation Summary Controller Battery Status set to Not fully Charged. EventCategory 6 (Primary Storage) ProbableCause 99 (low battery) ProbableCauseDescription Controller Battery Status Changed to Not Fully Charged NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
Property Name Property Implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Property Name IndicationTime Property Implementation Time of indication CIM_AlertIndication Description A Smart Array controller battery status changed to Failed. AlertingManagedElement WBEM Path to SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 8 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check battery connection and replace if necessary.
Property Name Property Implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated.
Property Name VariableTypes[] Property Implementation String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation Summary Controller cache status OK EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Controller Cache Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Cache status has changed to Temporarily Disabled. This may be caused by a rebuild or configuration change. Normal operation will return after background operations have completed. AlertingManagedElement WBEM Path to SMX_SAArrayController class.
Property Name Property Implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other system
Property Name Property Implementation FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation ProviderName HP Smart Array RecommendedActions Check the cache controller error code and run diagnostics.
Property Name Property Implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP_DeviceIndication: Enclosure Power Supply Status changed to Non Redundant 1-3-17 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem status has changed to non-redundant.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name HWSerialNumber Property Implementation Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Power Supply Status changed to OK (Redundant) 1-3-18 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to Fully Redundant.
Property Name Property Implementation ProbableCause 1 (Other) ProbableCauseDescription Redundant Power Supply Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name SystemVirtualUUID Property Implementation Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication Enclosure Location string HWLogicalLocation For example: Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Power Supply Status changed to Redundant Degraded 1-3-19 Property Name Property Implementation CIM_Indication IndicationIdent
Property Name Property Implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Power supply status Redundant Degraded EventCategory 17 (Primary Storage Power) ProbableCause 89 (Power supply failure) ProbableCauseDescription Redundant Power Supply Degraded NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indi
Property Name Property Implementation EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 307 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions No action is recommended.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
Property Name Property Implementation 2.2.0.
Property Name DeviceModel Property Implementation Enclosure Model string HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Critical 1-3-22 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status has changed to Critical.
Property Name Property Implementation ProbableCause 51 (Temperature Unacceptable ) ProbableCauseDescription Temperature Status Changed to Critical NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation a aggregate product environment in the format v..
Property Name SystemCreationClassName Property Implementation CreationClassName of the computer system generating the indication HP_AlertIndication Summary Fan status OK EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
Property Name Property Implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Property Name Property Implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 306 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
Property Name Property Implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
1 Smart Array View Class Data Sheet 1-1 Overview The HP Smart Array View Class data sheet describes host based Smart Array HBA’s and the attached devices. Note that current View Class implementation does not support externally attached Smart Array based MSA devices (e.g. MSA500, MSA20). 1-2 Class Implementations 1-2-1 HPVC_SAController HPVC_SAController represents the Smart Array HBA. There will be one instance per HBA.
Property Name Property Implementation CIM_ComputerSystem VMware_Controller HPVC_SAController 1-2-2 HPVC_SAControllerFirmware HPVC_SAControllerFirmware represents Smart Array controller firmware. There will be one instance per HBA. Table 2 – Class: HPVC_SAControllerFirmware Property Name Property Implementation CIM_ManagedElement ElementName Smart Array Controller X Note: VMware Virtual Infrastructure client requires controller name string X matches “vmwControllerX” reported in HPVC_SAControllerName.
Property Name Property Implementation CreationClassName HPVC_SABattery DeviceID Battery on HPSA X SystemCreationClassName SMX_ComputerSystem SystemName Server host name CIM_Battery BatteryStatus 1(Other) 2(Unknown) 3(Fully Charged) 4(Low) 5(Critical) 6(Charging) 7(Charging and High) 8(Charging and Low) 9(Charging and Critical) 10(Undefined) 11(Partially Charged) 12(Learning) 13(Overcharged) VMware_Battery HPVC_SABattery 1-2-4 HPVC_SAStorageExtent HPVC_SAStorageExtent represents physical disk a
Property Name HealthState Property Implementation 0 (Unknown) 5 (OK) 10 (Degraded/Warning) 15 (Minor Failure) 20 (Major Failure) 25 (Critical Failure) 30 (Non-recoverable Error) CIM_LogicalElement Caption Disk Y on HPSA X CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SAStorageExtent DeviceID HPVC_SAStorageExtent-- e.g.
Property Name ElementName Property Implementation Logical Volume Y on HPSA X : RAID level : Capacity : Associated Physical Disks : Detailed Status Associated Physical Disks reports a list of physical disks that are associated with this logical volume. Physical disk’s index should match the one reported in HPVC_StorageExtentElement Name. Detailed Status shows detailed volume status information when this logical volume is degraded or failed.
1 HP Insight Manager WBEM System Fan Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) System Fan provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
1-2-1 SMX_Fan Class The SMX_Fan class is used to model fans on servers. Fan numbers for existing instances do not change when other fans are added and removed. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this fan from the name displayed by the MP or iLO and the location. For example: Fan 1 at CabinetFan=01 Description of this fan, including ElementName, FanType and StatusDescription[0].
Property Name Property Implementation Fan 1 at CabinetFan=01 CIM_LogicalDevice CreationClassName SMX_Fan DeviceID Unique identifier for this fan instance. SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SMX_ComputerSystem.
Property Name Property Implementation This is a collection of all devices including fans that provide cooling. GroupStatusDescription Description ElementName Where: GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property. Cooling Collection CIM_SystemSpecificCollection InstanceID Unique identifier for this cooling collection instance.
CIM_ManagedElement Caption Short description of this redundancy set, for example: Cooling Redundancy Set Where: represents the number of the redundancy set instance. Description of this redundancy set Description For example: Cooling Redundancy Set is collection of fault tolerant fans that provide redundant cooling Where: represents the number of the redundancy set instance. User printable name for this cooling redundancy set.
Property Name Property Implementation Collection References HP_FanRedundancySet Member References HP_Fan 1-2-5 SMX_HostedFanRedundancySet Class The SMX_HostedFanRedundancySet class is used to represent an association between HP_FanRedundancySet and the computer system that contains this redundancy set. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation GroupComponent References HP_ComputerSystem PartComponent References HP_Fan 1-2-9 SMX_FanLocation Class The SMX_FanLocation class is used to model fan locations on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this fan location, including the name displayed by the MP or iLO.
1-2-10 SMX_FanElementLocation Class The SMX_FanElementLocation class is used to represent an association between the CIM_Location and CIM_ManagedElement classes. The following table lists the properties implemented. Property Name Property Implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location 1-2-11 SMX_FanModule Class The SMX_FanModule class is used to model physical fans on servers.
Property Name Property Implementation Description of the status of the fan corresponding to the OperationalStatus. StatusDescriptions[0] For example: Fan is operating properly – if OperationalStatus[0] is 2 (OK); Fan is degraded – if OperationalStatus[0] is 3 (Degraded) Fan has failed – if OperationalStatus is 6 (Error) 5 (OK) – if fan is operating properly; HealthState 10 (Degraded) if fan is degraded 20 (Major Failure) – if fan has failed Name of this fan module.
The following table lists the properties implemented. Property Name Property Implementation Antecedent References HP_FanModule Dependent References HP_Fan 1-2-14 SMX_FanSlot Class The SMX_FanSlot class is used to model physical fan slots on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Short description of this fan slot, to include the number and location.
Property Name Property Implementation Number 1-2-15 Where: represents the number of the fan slot. SMX_SystemFanSlot Class The SMX_SystemFanSlot class implements the HP_FanSlot class and association the HP_ComputerSystemChassis instance with HP_FanSlot. The following table lists the properties implemented.
Property Name ElementName Property Implementation Short description of the fan speed sensor from the name displayed by the MP or iLO and the location.
Property Name BaseUnits Property Implementation 19 (RPM) 65 (Percentage) RateUnits 0 (None) UnitModifier 0 1-2-18 SMX_SystemFanSensor SMX_SystemFanSensor is used to represent an association between SMX_FanSpeedSensor and the computer system that contains this fan sensor.
Property Name Property Implementation EventTime Time of the event or time of the indication if event time unknown. SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses OSType For example: 01.05.00 Contains a list of all the IP addresses of the computer system generating the indication.
The following indications are implemented for Proliant server platforms where available. System Fan indications are described below. 1-3-2 HP_DeviceIndication: Fan Removed Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fan has been removed Where: is the fan number that was removed. AlertingManagedElement WBEM Path of the SMX_Fan instance.
Property Name Property Implementation A fan has been inserted. Description Where: is the SMX_Fan.Caption for the fan that has been inserted. AlertingManagedElement WBEM Path of SMX_Fan instance representing the inserted fan. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 2 ProviderName HP Cooling RecommendedActions No action is recommended.
Property Name RecommendedActions Property Implementation Please Check the failed fan and replace if necessary. HP_AlertIndication Summary Fan failed EventCategory 23 (System Cooling) ProbableCause 94 (Fan Failure) ProbableCauseDescription Fan Failed 1-3-5 HP_DeviceIndication: Fan Repaired Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A fan has been repaired. The fan is now operating properly.
1-3-6 HP_DeviceIndication: Fan Degraded . Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication A fan has degraded. Description Where: is the SMX_Fan.Caption for the fan that has degraded. AlertingManagedElement WBEM Path of SMX_Fan instance representing the degraded fan.
Property Name Property Implementation redundancy. AlertingManagedElement WBEM Path of SMX_FanRedundancySet instance representing the redundancy set with reduced redundancy. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 5 ProviderName HP Cooling RecommendedActions No action is recommended.
Property Name RecommendedActions Property Implementation Check the fan configuration and check the status of the cooling redundancy. Ensure the system is being cooled adequately. Add or replace fans if necessary.
Property Name Property Implementation ProbableCauseDescription Cooling Redundancy has been Restored 1-3-10 HP_DeviceIndication: Fan Redundancy Failed Important: This indication is not supported on HP ProLiant systems because redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Cooling redundancy for the system has failed.
1 HP Insight Management WBEM System Memory Provider The HP Insight Management Web-Based Enterprise Management (WBEM) System Memory provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory on HP servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Memory Profile HP WBEM TC 1.0 HP Memory Physical Asset Profile HP WBEM TC 1.0 HP Location Profile HP WBEM TC 1.2.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
implementation. When the Property Implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis. If other values are returned, a problem is indicated. Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity (cellular and non-cellular) systems. The location related properties and implementation values are determined based on the server type so they may differ.
Property Name Property Implementation 5 (OK), when OperationalStatus[0] = 2 (OK) HealthState 0 (Unknown), when OperationalStatus[0] = 0 (Unknown) 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) Name System Memory CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_Memory DeviceID HPQ:SMX_Memory:000 SystemCreationClassName Same value as SMX_ComputerSyste
Property Name Property Implementation HP_Memory SMX_Memory 1-2-2 SMX_SystemMemory Class The SMX_SystemMemory class represents an association between SMX_Memory and the computer system that contains the memory. There is one instance of this class. The following table lists the properties implemented.
Property Name Property Implementation Enumerator indicating the memory module operational status. OperationalStatus[0] contains overall memory module status OperationalStatus OperationalStatus[1] contains detailed memory module status (as needed) For details, see “Properties for Memory Module Status”.
Property Name Property Implementation CIM_PhysicalComponent RemovalConditions 3 (Removable when off) CIM_Chip CIM_PhysicalMemory DataWidth Data width of memory module in bits Capacity Total capacity of memory module in bytes InterleavePosition Position of memory module in an interleave.
Property Name Property Implementation An array that contains raw Serial Presence Detect information for the memory module. Each array element contains a byte of the Spd. Spd This property is conditional; it is populated if the data is available.
Property Name Property Implementation Enumerator indicating the memory board operational status. OperationalStatus[0] contains overall memory board status OperationalStatus OperationalStatus[1] contains detailed memory board status (as needed) For details, see “Properties for Memory Board Status”.
Property Name Property Implementation Removal conditions of the memory board: When the memory board is the system board: RemovalConditions 2 (Not Applicable) When the memory board is not the system board: 3 (Removable when off) 4 (Removable when on or off) PackageType 9 (Module/Card) CIM_Card HostingBoard True – memory board is on the baseboard.
OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Condition failure warranty. Correctable error threshold for pre-failure warranty has been exceeded Memory board has a configuration 3 (Degraded) error, e.g. there is a problem with the board release latch (unlock error) or there is an improper Degraded configuration of memory modules on the board.
Property Name Property Implementation CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] = 2 (OK) StatusDescriptions StatusDescriptions[0] = Memory module slot status:OK HealthState 5 (OK) Memory Module . Name Refer to “Physical Location” for more information. CIM_PhysicalElement CreationClassName SMX_MemoryModuleSlot Tag Opaque key of the form: HPQ:SMX_MemoryModuleSlot: Description ElementName Memory Module .
Property Name Property Implementation CIM_ManagedElement Caption Memory Board Slot . Refer to “Physical Location” for more information. CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] = 2 (OK) StatusDescriptions StatusDescriptions[0] = Memory board slot status: OK HealthState 5 (OK) Memory Board Slot . Name Refer to “Physical Location” for more information.
The following table lists the properties implemented. Property Name Property Implementation CIM_ElementInConnector HP_MemoryModuleInSlot SMX_MemoryModuleInSlot Antecedent References SMX_MemoryModuleSlot Dependent References SMX_MemoryModule 1-2-9 SMX_MemoryBoardInSlot Class The SMX_MemoryBoardInSlot class represents the association between an SMX_MemoryBoard and the SMX_MemoryBoardSlot where it resides. The following table lists the properties implemented.
1-2-11 SMX_MemoryModuleSlotLocation Class The SMX_MemoryModuleSlotLocation class extends the CIM_Location class and represents memory module slot locations on HP servers. There is an instance of this class for each memory module slot in the system (whether the slot is occupied or not). The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Description ElementName Memory Module Socket Location .
Property Name Property Implementation Array indices will report as many of the following enumerated values as are applicable: 4 (Socket) 5 (Memory Board) LocationInfoDesc 7 (Cabinet) 10 (Cell) 14 (BladeBay) 15 (ProcessorBoard) SMX_MemoryModuleSlotLocation 1-2-12 SMX_MemoryBoardSlotLocation Class The SMX_MemoryBoardSlotLocation class extends the CIM_Location class and represents memory board slot locations on HP servers.
Property Name Property Implementation Opaque key. ElementLocationTag For example, for memory board, cartridge, or processor number 1: FF-FF-FF-FF-01-FF-FF-7A ElementLocationTagDesc 9 (Memory Board) / 13 (Processor Board) LocationInformation[0] text: Where: is the board/cartridge/processor number LocationInformation Location information will contain a numeric string representing the unique location identifier of each object type described by the corresponding LocationInfoDesc index.
1-2-14 SMX_MemoryBoardSlotElementLocation Class The SMX_MemoryBoardSlotElementLocation class extends the CIM_ElementLocation class and is used to associate a memory board slot (SMX_MemoryBoardSlot) with its corresponding location (SMX_MemoryBoardSlotLocation). There is an instance of this class for each memory board slot in the system (whether the slot is occupied or not). The following table lists the properties implemented.
CIM_Container HP_SystemMemoryBoard SMX_SystemMemoryBoard GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_MemoryBoard 1-2-17 SMX_MemoryRedundancySet Class The SMX_MemoryRedundancySet class represents memory board redundancy on HP servers supporting Advanced Memory Protection (AMP). There is one instance of this class on systems supporting AMP. This class is not instantiated on non-AMP systems. The following table lists the properties implemented.
Property Name Property Implementation Represents the current memory redundancy status as follows: 2 (Fully Redundant) System is operating properly in the Advanced Memory Protection mode given in the TargetConfiguration property. 3 (Degraded Redundancy) RedundancyStatus Degraded Redundancy can occur in either of the following conditions: • System is not operating in the TargetConfiguration mode (the CurrentConfiguration mode does not match the TargetConfiguration mode).
Property Name Property Implementation The desired or targeted mode of the Advanced Memory Protection system.
Property Name Property Implementation Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property SMX_MemoryRedundancySet.RedundancyStatus. • If no instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined by the ‘worstof’ algorithm for physical memory boards and memory modules.
- 0 (Unknown) 3 (Degraded) 3 (Degraded) - 0 (Unknown) 0 (Unknown) 0 (Unknown) 1-2-19 SMX_HostedMemoryCollection Class The SMX_HostedMemoryCollection class represents an association between SMX_MemoryCollection and the computer system that contains this collection. The following table lists the properties implemented.
1-2-21 SMX_MemberOfMemoryRedundancySet Class The SMX_MemberOfMemoryRedundancySet class represents an association between SMX_MemoryBoard and SMX_MemoryRedundancySet. The following table lists the properties implemented.
CIM_Container HP_SystemMemoryModuleSlot SMX_SystemMemoryModuleSlot GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_MemoryModuleSlot 1-2-24 SMX_SystemMemoryBoardSlot Class The SMX_SystemMemoryBoardSlot class represents an association between SMX_MemoryBoardSlot and SMX_ComputerSystemChassis. There is an instance of this class for each memory board slot in the chassis (whether the slot is occupied or not). The following table lists the properties implemented.
Property Name Property Implementation IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses OSType For example: 01.11.
Property Name Property Implementation RackName Rack name, if one exists RackUUID Rack Unique Identifier, if one exists BladeName HP_ComputerSystem.Name BladeBay HP_BladeCSLocation.LocationInformation[0] SMX_MemoryIndication: Memory Module Predictive Failure 1-3-2 Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description A memory module has failed or is predicted to fail.
1-3-3 SMX_MemoryIndication: Memory Board Error Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A memory board has an error. (MemoryBoardCaption) Description Where: MemoryBoardCaption is the SMX_MemoryBoard.Caption for the failing memory board.
Property Name Property Implementation Where: TargetConfiguration is SMX_MemoryRedundancySet.TargetConfiguration. AlertingManagedElement WBEM Path of SMX_MemoryRedundancySet instance representing the Memory Redundancy. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 3 ProviderName HP Memory RecommendedActions Check the Advanced Memory Protection configuration and replace the memory board and memory modules as necessary.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 4 ProviderName HP Memory RecommendedActions No action is recommended.