4 Important notes and recommendations
Multiple 9006 Traps may be generated on ProLiant DL360 G7, ProLiant DL380 G7, and ProLiant
DL580 G7 Servers using VMware ESXi Server 4.0 and 4.1 with Integrated Lights-Out 3 (iLO 3) with
SNMP enabled
Provider portion of the fix for the issue where multiple 9006 Traps may be generated on ProLiant
DL360 G7, ProLiant DL380 G7, and ProLiant DL580 G7 Servers using VMware ESXi Server 4.1
with Integrated Lights-Out 3 (iLO 3) with SNMP enabled is included in this release. To completely
fix this issue, update to IntegratedLights-Out 3 (iLO 3) Firmware Version 1.26 (or later), available
for download at the following:http://www.hp.com/support/iLO3.
Administrators of SANs on VMware ESXi 4.1 Update 2 hosts are unable to communicate with
Emulex HBAs using the Emulex OneCommand Plug-in 1.0 for VMware vCenter
When using the VMware vCenter Plug-in and the Emulex CIM Provider Package 3.2.30 on SANs
running VMware ESXi 4.x, a pop-up message appears when attempting to communicate with the
Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter. For additional information, see http://
h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c03015899.