HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
System
Temperature Sensor
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded
Property name
Property implementation
VariableNames Contains the temperature sensor threshold property
name that sets a value:
UpperThresholdNonCritical
UpperThresholdCritical
UpperThresholdFatal
VariableTypes
9 (sint32)
VariableValues SMX_NumericSensor UpperThresholdNonCritical,
UpperThresholdCritical, or UpperThresholdFatal
property value that is set for the temperature sensor
detecting the exceeded threshold
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
Table 11-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication