HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

System
Temperature Sensor
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded
Property name
Property implementation
AlertingManagedElement WBEM path of the SMX_NumericSensor instance
representing the temperature sensor detecting the
exceeded threshold
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
System Temperature
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Temperature threshold exceeded detected
EventCategory
23 (System Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription
Temperature Threshold Exceeded Detected
ProviderVersion
For Example: 2.2.0.0
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication