HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Table 16-87 HP_DeviceIndication: Enclosure Fan status changed to Degraded
Property name
Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-2-18 Enclosure Fan Status change to Failure
Table 16-88
HP_DeviceIndication: Enclosure Fan status changed to Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan Status changed to Failure. An
enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure normal
operation.
AlertingManagedElement
WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
306
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.