HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Table 16-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
Property implementation
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-2-16 Enclosure Fan Status Changed to OK
Table 16-86 HP_DeviceIndication: Enclosure Fan status changed to OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status has changed from a
non-OK state to OK.
AlertingManagedElement
WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
304
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan status OK
EventCategory
24 (Primary Storage Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Status Changed to OK
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication