HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Table 16-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor Status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
AlertingManagedElement
WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
308
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Temperature sensor status Warning Condition
EventCategory
24 (Primary Storage Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription
Temperature Status Changed to Warning Condition
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
•
On ESXi, 39(VM)
• On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the
format: <major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication