HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Table 16-80 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
HP_AlertIndication
Summary
Power Supply status Non-Redundant
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses List of all the IP addresses of the computer system
generating the indication
OSType
On ESXi, 39(VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the following
format: <major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames
FailureDescription
VariableTypes
1 (String)
VariableValues Short Description of failure
In some cases, the property VariableValues can have
N/A or “” values.
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists