HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Table 16-74 HP_DeviceIndication: Physical Drive status ERROR
Property name
Property implementation
ImpactedDomain
•
3 (Enclosure) for c-Class blade systems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string
1-2-5 Physical Drive status REBUILDING
Table 16-75 HP_DeviceIndication: Physical Drive status REBUILDING
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity Severity
For example, 2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication