HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
Table 9-28
HP_DeviceIndication: Power SupplyRedundancy Failed
Property name
Property implementation
ProviderName
HP Power
RecommendedActions Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power
supplies if necessary.
HP_AlertIndication
Summary
Power redundancy failed
EventCategory
16 (System Power)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Power Redundancy has failed
1-4-11 HP_DeviceIndication: Power Supply Redundancy
Restored
Table 9-29 HP_DeviceIndication: Power Supply Redundancy Restored
Property name
Property implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description Power redundancy for the system has been restored.
(RedundancySetCaption), where RedundancySetCaption
is SMX_PowerRedundancySet.Caption of the
redundancy set the power redundancy set with restored
redundancy
AlertingManagedElement WBEM Path of SMX_PowerRedundancySet instance
representing the power redundancy set with restored
redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
8
ProviderName
HP Power
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Power redundancy restored