1-4-9 HP_DeviceIndication: Power Supply
Redundancy Lost
Table 9-27 HP_DeviceIndication: Power Supply Redundancy Lost
Property name
Property implementation
ProviderName
HP Power
RecommendedActions Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power
supplies if necessary.
HP_AlertIndication
Summary
Power redundancy lost.
EventCategory
16 (System Power)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Power Redundancy has been Lost
1-4-10 HP_DeviceIndication: Power Supply Redundancy
Failed
This indication is not supported on ProLiant systems since redundancy set failure, which is failure
beyond redundancy lost, will cause system shutdown.
Table 9-28
HP_DeviceIndication: Power SupplyRedundancy Failed
Property name
Property implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description Power redundancy has been lost.
(RedundancySetCaption)where RedundancySetCaption
represents the SMX_PowerRedundancySet.Caption for
the redundancy set that failed redundancy.
AlertingManagedElement WBEM path of the SMX_PowerRedundancySet
instance representing the redundancy set where
redundancy failed
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
10