HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Table 9-23
Provider Indication Common Properties
Property name
Property implementation
SystemFirmwareVersion Array of firmware versions of the computer system
generating the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
1-4-2 HP_DeviceIdentification: Power Supply Removed
The following indications are implemented for ProLiant server platforms where available. System
Power Supply indications are described below.
Table 9-24
HP_DeviceIdentification: Power Supply Removed
Property name
Property implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description A power supply has been removed. (Power Supply),
where Power Supply is the system power supply that
was removed
AlertingManagedElement
WBEM path of the SMX_WinPowerSupply instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Power
RecommendedActions Check the system power supply configuration. Verify
that this power supply was removed intentionally.
HP_AlertIndication