HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Table 9-3
Class: SMX_PowerCollection
Property name
Property implementation
GroupStatusDescriptions[0] Unknown status for power supplies, if
GroupOperationalStatus[0] is 0 (Unknown)
Power supplies are operating properly, if
GroupOperationalStatus[0] is 2 (OK)
Power supplies are degraded, if
GroupOperationalStatus[0] is 3 (Degraded)
Power supplies have failed, if
GroupOperationalStatus[0] is 6 (Error)
1-3-3 SMX_PowerRedundancySet
SMX_PowerRedundancySet is used to model power supply redundancy sets on Servers.
Table 9-4 Class: SMX_PowerRedundancySet
Property name
Property implementation
CIM_ManagedElement
Caption Power Redundancy Set n, where n represents the
number of the redundancy set instance
Description Power Redundancy Set n is collection of fault tolerant
power supplies that provide redundant power.
n represents the number of the redundancy set instance
ElementName Power Redundancy Set n, where n represents the
number of the redundancy set instance
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this power redundancy instance
CIM_RedundancySet
MaxNumberSupported The maximum number of power supplies supported for
this redundancy set
MinNumberNeeded The minimum number of power supplies needed to
function
TypeOfSet
3 (Load Balanced)
LoadBalanceAlgorithm
0 (Unknown)