HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

1-3-2 SMX_PowerCollection
SMX_PowerCollection is used to model power supply collections on Servers. There will be one
instance of this class on systems modeling power supplies.
Table 9-3
Class: SMX_PowerCollection
Property name
Property implementation
CIM_ManagedElement
Caption
Power Collection
Description This is a collection of all devices including power
supplies that provide power. GroupStatusDescription.
Where GroupStatusDescription
represents the value of
the GroupStatusDescriptions[0] property
ElementName
Power Collection
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this power collection instance
HP_GroupSystemSpecificCollection
GroupOperationalStatus[0] Represents the most severe power redundancy status
and non-fault tolerant power supply operational status:
0 (Unknown) If power collection status is unknown
2 (OK) If power supplies are operating properly
3 (Degraded) If no
SMX_PowerSupply.OperationalStatus[0] for all non-
fault tolerant power supplies report 6 (Error) and
SMX_PowerRedundancySet.RedundancyStatus for any
power redundancy sets report 3 (Degraded
Redundancy) or 4 (Redundancy Lost) and no power
redundancy sets report 5 (Overall Failure).
6 (Error) If SMX_PowerSupply.OperationalStatus[0]
for any non-fault tolerant power supplies report 6
(Error) or if
SMX_PowerRedundancySet.RedundancyStatus for any
power redundancy sets report 5 (Overall Failure).
Note: If the system starts up with a redundancy status
set to 4 (Redundancy Lost) and no power supplies have
been removed or failed, the GroupOperationalStatus
will be set to 2 (OK) because this is a valid
configuration.