HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets

Table 9-2
Class: HP_PowerSupply
Property name
Property implementation
StatusDescriptions[0] Description of the status of the power supply
corresponding to the OperationalStatus.
For example: Power Supply is operating properlyif
OperationalStatus[0] is 2 (OK);
Power Supply is degraded if OperationalStatus[0] is
3 (Degraded)
Power Supply has failed if OperationalStatus is 6
(Error)
StatusDescriptions[1]
Power Supply Extended status description. See Profile.
HealthState 5 (OK)if the power supply is operating properly
10 (Degraded) if power supply is degraded
20 (Major Failure)if the power supply has failed
Name Name of this power supply from the name displayed
by the MP or iLO and its location. For example, Power
Supply 1 at PowerSupplySlot=2 Power supply 1a at
PowerSupplySlot=2
TimeOfLastStateChange Time that state last changed for power
supply. 0 if it has not changed since
provider startup.
CIM_LogicalDevice
CreationClassName
SMX_PowerSupply
DeviceID
Unique identifier for this power supply instance
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
SystemName
SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_PowerSupply
TotalOutputPower Power reported in Milliwatts .The value 0 denotes
‘unknown’ output power.
HP_PowerSupply
PowerSupplyType Enumeration describing the type of power supply (see
MOF)