HP integrated VMware ESXi 4.1 U2 June 2012 Datasheets
System Fan
1-4-9 HP_DeviceIndication: Fan Redundancy
Restored
Table 8-29
HP_DeviceIndication: Fan Redundancy Restored
Property name
Property implementation
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Cooling redundancy restored
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Cooling Redundancy has been Restored
1-4-10 HP_DeviceIndication: Fan Redundancy Failed
The redundancy failed indication is not supported on ProLiant systems since redundancy
set failure, which is failure beyond redundancy lost, will cause system shutdown.
Table 8-30 HP_DeviceIndication: Fan Redundancy Failed
Property name
Property implementation
CIM_Indication
PerceivedSeverity
5 (Major))
CIM_AlertIndication
Description Cooling redundancy for the system has failed.
(Redun dancySetCaption)
where RedundancySetCaption is
SMX_FanRedundancySet.Caption of the cooling
redundancy set with failed redundancy
AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance
representing the cooling redundancy set with failed
redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
10
ProviderName
HP Cooling
RecommendedActions
Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.